Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 1057–1080 of 10248
R448A compressor — 119.8 kW cooling, 29.39 kW input, COP 4.07 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 68.3 kW cooling, 24.16 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 68.3 kW cooling, 24.16 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
R407A compressor — 116.4 kW cooling, 36.80 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 110.6 kW cooling, 34.20 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R407F compressor — 97.0 kW cooling, 30.66 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.
R407F compressor — 116.4 kW cooling, 36.80 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 106.1 kW cooling, 37.01 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 126.0 kW cooling, 41.54 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 146.7 kW cooling, 41.72 kW input, COP 3.51 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 126.3 kW cooling, 44.87 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 80.6 kW cooling, 35.01 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 115.2 kW cooling, 49.10 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.
R407A compressor — 144.7 kW cooling, 42.51 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 98.9 kW cooling, 66.39 kW input, COP 1.49 at the AHRI 7.2/54.4 °C rating point.
R407F compressor — 99.3 kW cooling, 15.55 kW input, COP 6.39 at the AHRI 7.2/54.4 °C rating point.
R407F compressor — 119.2 kW cooling, 18.66 kW input, COP 6.39 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 146.7 kW cooling, 41.72 kW input, COP 3.51 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 90.0 kW cooling, 28.92 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 84.2 kW cooling, 29.98 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 84.2 kW cooling, 29.98 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 127.9 kW cooling, 44.34 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 90.0 kW cooling, 28.92 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 124.0 kW cooling, 48.84 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point.