Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 11,569–11,592 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Danfoss MLZ026T4 (R407C scroll, 50 Hz, MT) Catalog | Compressors | Danfoss | R407C compressor — 9.6 kW cooling, 3.30 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland ZS13KAE-TF5 (R22 scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R22 compressor — 5.7 kW cooling, 1.98 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss MTZ050-3 (R448A hermetic reciprocating, 60 Hz, MT) Catalog | Compressors | Danfoss | R448A compressor — 13.5 kW cooling, 5.01 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland ZW34KAE-PFS (R407C scroll, 50 Hz, HP) Catalog | Compressors | Copeland | R407C compressor — 9.9 kW cooling, 2.58 kW input, COP 3.83 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Danfoss MLZ026T4 (R407C scroll, 60 Hz, MT) Catalog | Compressors | Danfoss | R407C compressor — 11.5 kW cooling, 3.90 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland ASE28C5E-IAV (R404A hermetic recip, 60 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 0.52 kW cooling, 0.45 kW input, COP 1.17 at -20/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ050-3 (R449A hermetic reciprocating, 60 Hz, MT) Catalog | Compressors | Danfoss | R449A compressor — 13.5 kW cooling, 5.01 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland CR30K6ME-PF1 (R407C hermetic recip, 50 Hz, HT) Catalog | Compressors | Copeland | R407C compressor — 6.9 kW cooling, 2.28 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss MLZ026T4 (R407F scroll, 50 Hz, MT) Catalog | Compressors | Danfoss | R407F compressor — 9.7 kW cooling, 3.66 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland CS27K7ME-PFZ (R404A hermetic recip, 50 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 4.9 kW cooling, 2.96 kW input, COP 1.66 at -20/40 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss MTZ050-3 (R452A hermetic reciprocating, 60 Hz, MT) Catalog | Compressors | Danfoss | R452A compressor — 13.3 kW cooling, 5.33 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland RST70C1E-PFV (R449A hermetic recip, 60 Hz, MT) Catalog | Compressors | Copeland | R449A compressor — 1.3 kW cooling, 0.82 kW input, COP 1.55 at -20/40 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ026T4 (R407F scroll, 60 Hz, MT) Catalog | Compressors | Danfoss | R407F compressor — 11.9 kW cooling, 4.29 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland YB17K1E-TFD (R407A scroll, 60 Hz, MT) Catalog | Compressors | Copeland | R407A compressor — 5.0 kW cooling, 1.91 kW input, COP 2.60 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ050-3 (R454A hermetic reciprocating, 60 Hz) Catalog | Compressors | Danfoss | R454A compressor — 14.9 kW cooling, 5.45 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland YBD24K1E-TFD (R454A scroll, 60 Hz, MT) Catalog | Compressors | Copeland | R454A compressor — 7.8 kW cooling, 2.95 kW input, COP 2.65 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ026T4A (R134a scroll, 50 Hz, MT) Catalog | Compressors | Danfoss | R134a compressor — 6.3 kW cooling, 2.06 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland YF05KAU-TF5 (R290 scroll, 60 Hz, LT) Catalog | Compressors | Copeland | R290 compressor — 1.0 kW cooling, 0.77 kW input, COP 1.31 at -35/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ050-3 (R454C hermetic reciprocating, 60 Hz) Catalog | Compressors | Danfoss | R454C compressor — 12.6 kW cooling, 4.51 kW input, COP 2.80 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland YFH05KAE-TF5 (R407F scroll, 50 Hz, LT) Catalog | Compressors | Copeland | R407F compressor — 0.91 kW cooling, 0.97 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss MLZ026T4A (R134a scroll, 60 Hz, MT) Catalog | Compressors | Danfoss | R134a compressor — 7.9 kW cooling, 2.48 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland YH16K1E-TFD (R513A scroll, 60 Hz, HP) Catalog | Compressors | Copeland | R513A compressor — 17.1 kW cooling, 5.56 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss MTZ050-3 (R455A hermetic reciprocating, 60 Hz) Catalog | Compressors | Danfoss | R455A compressor — 13.7 kW cooling, 4.85 kW input, COP 2.82 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland YS13KSE-TF5 (R454C scroll, 50 Hz, EM) Catalog | Compressors | Copeland | R454C compressor — 1.7 kW cooling, 1.13 kW input, COP 1.50 at -25/40 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one