Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 13,801–13,824 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss MLZ048T2C (R404A scroll, 50 Hz, MT) CatalogCompressorsDanfossR404A compressor — 16.7 kW cooling, 6.34 kW input, COP 2.63 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZB15KNE-TF7 (R22 scroll, 60 Hz, HT) CatalogCompressorsCopelandR22 compressor — 6.7 kW cooling, 2.39 kW input, COP 2.79 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss MLZ048T2C (R404A scroll, 60 Hz, MT) CatalogCompressorsDanfossR404A compressor — 20.2 kW cooling, 7.51 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZBD57KCE-TF5 (R134A scroll, 60 Hz, HT) CatalogCompressorsCopelandR134a compressor — 16.5 kW cooling, 5.50 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ048T2C (R448A scroll, 50 Hz, MT) CatalogCompressorsDanfossR448A compressor — 17.5 kW cooling, 6.31 kW input, COP 2.77 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZF09K4E-TF5 (R407F scroll, 50 Hz, LL) CatalogCompressorsCopelandR407F compressor — 2.3 kW cooling, 1.22 kW input, COP 1.90 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ048T2C (R448A scroll, 60 Hz, MT) CatalogCompressorsDanfossR448A compressor — 21.7 kW cooling, 7.53 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZP83KZE-TFD (R410A scroll, 60 Hz, AC) CatalogCompressorsCopelandR410A compressor — 24.7 kW cooling, 7.73 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ048T2C (R449A scroll, 50 Hz, MT) CatalogCompressorsDanfossR449A compressor — 17.5 kW cooling, 6.31 kW input, COP 2.77 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZR38K5E-TFD (R22 scroll, 50 Hz, AC) CatalogCompressorsCopelandR22 compressor — 9.0 kW cooling, 2.85 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MLZ048T2C (R449A scroll, 60 Hz, MT) CatalogCompressorsDanfossR449A compressor — 21.7 kW cooling, 7.53 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZS21KAE-TF5 (R507 scroll, 60 Hz, EM) CatalogCompressorsCopelandR507 compressor — 4.6 kW cooling, 2.45 kW input, COP 1.88 at -25/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ048T2C (R452A scroll, 50 Hz, MT) CatalogCompressorsDanfossR452A compressor — 17.5 kW cooling, 6.58 kW input, COP 2.66 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YB36K1E-TFD (R1234yf scroll, 60 Hz, MT) CatalogCompressorsCopelandR1234yf compressor — 6.8 kW cooling, 2.54 kW input, COP 2.67 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ048T2C (R452A scroll, 60 Hz, MT) CatalogCompressorsDanfossR452A compressor — 21.1 kW cooling, 7.90 kW input, COP 2.67 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YF07KSE-TF5 (R407A scroll, 60 Hz, LL) CatalogCompressorsCopelandR407A compressor — 2.0 kW cooling, 1.59 kW input, COP 1.27 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ048T2C (R454A scroll, 50 Hz) CatalogCompressorsDanfossR454A compressor — 18.4 kW cooling, 6.93 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YS24KAE-PFJ (R407A scroll, 50 Hz, EM) CatalogCompressorsCopelandR407A compressor — 3.1 kW cooling, 2.05 kW input, COP 1.49 at -25/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ048T2C (R454A scroll, 60 Hz) CatalogCompressorsDanfossR454A compressor — 22.3 kW cooling, 8.04 kW input, COP 2.77 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZB15KNE-TF7 (R448A scroll, 60 Hz, EM) CatalogCompressorsCopelandR448A compressor — 6.4 kW cooling, 2.52 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss MLZ048T2C (R454C scroll, 50 Hz) CatalogCompressorsDanfossR454C compressor — 16.1 kW cooling, 5.27 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZBD57KCE-TF5 (R22 scroll, 60 Hz, HT) CatalogCompressorsCopelandR22 compressor — 25.6 kW cooling, 8.40 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ048T2C (R454C scroll, 60 Hz) CatalogCompressorsDanfossR454C compressor — 19.4 kW cooling, 6.53 kW input, COP 2.97 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZF09K4E-TF5 (R407F scroll, 60 Hz, LL) CatalogCompressorsCopelandR407F compressor — 2.8 kW cooling, 1.47 kW input, COP 1.90 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…574575576577578…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one