Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 1,393–1,416 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss WSH184-4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 39.1 kW cooling, 13.62 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEHT409U (R290 variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.49 kW cooling, 0.31 kW input, COP 1.59 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW110A2-100 (R22 heat-pump water heater scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR22 compressor — 12.1 kW cooling, 3.89 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AWA2460ZXD (R449A hermetic, LBP, ARI, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 1.3 kW cooling, 1.32 kW input, COP 0.96 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DJXF76K0-AWX (R22 Discus recip, 60 Hz, LT) CatalogCompressorsCopelandR22 compressor — 8.9 kW cooling, 8.71 kW input, COP 1.02 at -45/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss CH290-4BI (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 65.2 kW cooling, 22.51 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEHU413U (R290 variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.68 kW cooling, 0.46 kW input, COP 1.50 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF13A7G-Q100 (R22 low-temperature freezing scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 1.7 kW cooling, 1.49 kW input, COP 1.16 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AWR5532EXC (R22 hermetic, AC, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 7.9 kW cooling, 2.72 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJXR19ME-AWX (R134A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR134a compressor — 62.1 kW cooling, 19.53 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss DCJ091T2A (R410A scroll, 50 Hz) CatalogCompressorsDanfossR410A compressor — 19.6 kW cooling, 7.22 kW input, COP 2.71 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEMC5C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.63 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH104T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR407C compressor — 12.3 kW cooling, 3.87 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AWS2495ZXG (R404A hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 1.6 kW cooling, 1.20 kW input, COP 1.30 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DK3F63KE-TSK (R448A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR448A compressor — 15.6 kW cooling, 9.01 kW input, COP 1.73 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSF090-4 (R32 scroll, 60 Hz, HT) CatalogCompressorsDanfossR32 compressor — 26.9 kW cooling, 8.68 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEMT11C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.19 kW cooling, 0.12 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM102E1G-100 (R452A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR452A compressor — 15.4 kW cooling, 6.10 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh CAJ4517Z (R404A recip, EN 12900) CatalogCompressorsTecumsehR404A compressor — 3.2 kW cooling, 1.60 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DKNF63KE-TSK (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 14.7 kW cooling, 8.37 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSG295-4 (R1234ze(E) scroll, 50 Hz, MT) CatalogCompressorsDanfossR1234ze(E) compressor — 67.7 kW cooling, 21.34 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEMX11C+ (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.18 kW cooling, 0.12 kW input, COP 1.55 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF125E1G-V100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 16.7 kW cooling, 8.14 kW input, COP 2.05 at -30/35 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh FH2480P-KZ1A (R455A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR455A compressor — 1.1 kW cooling, 1.04 kW input, COP 1.02 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
‹ Previous1…5758596061…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one