Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 15,313–15,336 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Copeland ZF54KQE-TFD (R22 scroll, 60 Hz, LL) Catalog | Compressors | Copeland | R22 compressor — 11.4 kW cooling, 7.62 kW input, COP 1.49 at -35/30 °C (evaporating/condensing), inside its published envelope. | APAC | Open in the builder |
| Copeland ZB57KQE-TFD (R513A scroll, 50 Hz, HT) Catalog | Compressors | Copeland | R513A compressor — 13.6 kW cooling, 4.73 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZF54KQE-TFD (R404A scroll, 50 Hz, LL) Catalog | Compressors | Copeland | R404A compressor — 12.2 kW cooling, 8.23 kW input, COP 1.48 at -35/35 °C (evaporating/condensing), inside its published envelope. | APAC | Open in the builder |
| Copeland ZB57KQE-TFD (R513A scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R513A compressor — 16.3 kW cooling, 5.68 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZF54KQE-TFD (R404A scroll, 60 Hz, LL) Catalog | Compressors | Copeland | R404A compressor — 14.7 kW cooling, 9.88 kW input, COP 1.48 at -35/35 °C (evaporating/condensing), inside its published envelope. | APAC | Open in the builder |
| Copeland ZB58K5E-TFD (R134A scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R134a compressor — 16.8 kW cooling, 5.76 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Copeland ZF54KQE-TFD (R407A scroll, 50 Hz, LL) Catalog | Compressors | Copeland | R407A compressor — 10.1 kW cooling, 7.46 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope. | APAC | Open in the builder |
| Copeland ZB58K5E-TFD (R404A scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 13.9 kW cooling, 4.47 kW input, COP 3.11 at -15/30 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Copeland ZF54KQE-TFD (R407A scroll, 60 Hz, LL) Catalog | Compressors | Copeland | R407A compressor — 12.1 kW cooling, 8.96 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope. | APAC | Open in the builder |
| Copeland ZB58K5E-TFD (R507 scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R507 compressor — 14.0 kW cooling, 4.65 kW input, COP 3.02 at -15/30 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Copeland ZF54KQE-TFD (R407C scroll, 60 Hz, LL) Catalog | Compressors | Copeland | R407C compressor — 10.8 kW cooling, 8.38 kW input, COP 1.29 at -35/35 °C (evaporating/condensing), inside its published envelope. | APAC | Open in the builder |
| Copeland ZB58K5E-TFD (R513A scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R513A compressor — 16.7 kW cooling, 6.12 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Copeland ZF54KQE-TFD (R507 scroll, 50 Hz, LL) Catalog | Compressors | Copeland | R507 compressor — 15.1 kW cooling, 10.08 kW input, COP 1.50 at -35/35 °C (evaporating/condensing), inside its published envelope. | APAC | Open in the builder |
| Copeland ZB58KQE-TFD (R404A scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 20.3 kW cooling, 7.78 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZB58KQE-TFD (R404A scroll, 60 Hz, MD) Catalog | Compressors | Copeland | R404A compressor — 24.5 kW cooling, 9.47 kW input, COP 2.59 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZB64K5U-TFM (R290 scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R290 compressor — 24.4 kW cooling, 7.58 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Copeland ZB66K5E-TFD (R134A scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R134a compressor — 19.1 kW cooling, 6.47 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Copeland ZB66K5E-TFD (R404A scroll, 60 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 19.4 kW cooling, 6.21 kW input, COP 3.12 at -15/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Copeland ZB66K5E-TFD (R448A scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R448A compressor — 24.0 kW cooling, 8.29 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Copeland ZB66K5E-TFD (R448A scroll, 60 Hz, MT) Catalog | Compressors | Copeland | R448A compressor — 29.1 kW cooling, 10.06 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Copeland ZB66K5E-TFD (R507 scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R507 compressor — 16.0 kW cooling, 5.22 kW input, COP 3.07 at -15/30 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Copeland ZB66K5E-TFD (R513A scroll, 50 Hz, HT) Catalog | Compressors | Copeland | R513A compressor — 15.4 kW cooling, 5.45 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Copeland ZB66KCE-TF5 (R134A scroll, 50 Hz, HT) Catalog | Compressors | Copeland | R134a compressor — 15.9 kW cooling, 5.29 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Copeland ZB66KCE-TF5 (R404A scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 14.4 kW cooling, 5.76 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one