Baltimore Aircoil PFI-2012N-3D1DS-L2 closed-circuit cooler (216 tons, 951 kW) — modelled

Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Source: Baltimore Aircoil Product & Application Handbook volume VI, PFi engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json). The figures below come from this model run against that data; the manufacturer has not reviewed them. Are you Baltimore Aircoil? Claim this page.

CTI STD-201: the line, not this model — Baltimore Aircoil's PF Series line is certified (validation C11P-12R02), but this model is not named in the disclosure that covers it, so nothing is claimed for it here: the PF Series disclosure enumerates no models at all — it describes them through a sample model number and seven code tables, so nothing can be matched by name. What the model of it reads against the maker's published tables is a separate question.

by HVAC Builder

Open this system in HVAC Builder Load it into the 3D builder, adjust it to your project, and solve it against your own climate — or drop it into a building model and simulate a full year.

BAC's PFI-2012N-3D1DS-L2 — a PFi closed-circuit cooler, 216 nominal tons (951 kW): rated to cool 651 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 66.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Example713–1188 kW coolingEU

Example system. Published by HVAC Builder to show suppliers what their own page looks like. There is no company behind it and it is not a product offer — the specification is generic and the performance is solved from the model on this page.

Design-point performance

950.5 kWcooling
22.4 kWelectrical power
2082 l/hwater use
42.49system COP

Solved from this example's own model each time the page loads — the same numbers a supplier's page shows for their machine.

Component schedule

ComponentKindDuty
PFI-2012N-3D1DS-L2 fillwetPack-950.5 kW
PFI-2012N-3D1DS-L2 fanfan-22.4 kW
PFI-2012N-3D1DS-L2 tower-loop circulatorpump—