Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Listings
Showing 1–24 of 57
CaptiveAire CASRE11DD direct-drive up-blast centrifugal utility set (Catalog #110C, November 2024; 2326 rpm)
Fan rated 0.42 m³/s at 0.88 kW.
CaptiveAire CASRE13DD direct-drive up-blast centrifugal utility set (Catalog #110C, November 2024; 2133 rpm)
Fan rated 0.64 m³/s at 1.04 kW.
CaptiveAire CASRE15DD direct-drive up-blast centrifugal utility set (Catalog #110C, November 2024; 1675 rpm)
Fan rated 0.61 m³/s at 1.04 kW.
CaptiveAire CASRE18DD direct-drive up-blast centrifugal utility set (Catalog #110C, November 2024; 1638 rpm)
Fan rated 0.94 m³/s at 2.12 kW.
CaptiveAire CASRE20DD direct-drive up-blast centrifugal utility set (Catalog #110C, November 2024; 1468 rpm)
Fan rated 1.42 m³/s at 2.41 kW.
CaptiveAire CASRE24DD direct-drive up-blast centrifugal utility set (Catalog #110C, November 2024; 1284 rpm)
Fan rated 1.89 m³/s at 3.38 kW.
CaptiveAire DR10HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 1683 rpm)
Fan rated 0.17 m³/s at 0.10 kW.
CaptiveAire DR12HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 1644 rpm)
Fan rated 0.28 m³/s at 0.21 kW.
CaptiveAire DR180HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 1658 rpm)
Fan rated 1.65 m³/s at 2.91 kW.
CaptiveAire DR200HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 1465 rpm)
Fan rated 1.98 m³/s at 3.03 kW.
CaptiveAire DR240HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 1224 rpm)
Fan rated 3.30 m³/s at 4.01 kW.
CaptiveAire DR300HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 955 rpm)
Fan rated 4.01 m³/s at 5.27 kW.
CaptiveAire DR30HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 1751 rpm)
Fan rated 0.38 m³/s at 0.31 kW.
CaptiveAire DR33HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 1609 rpm)
Fan rated 0.33 m³/s at 0.29 kW.
CaptiveAire DR360HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 764 rpm)
Fan rated 6.14 m³/s at 6.50 kW.
CaptiveAire DR50HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 1476 rpm)
Fan rated 0.57 m³/s at 0.35 kW.
CaptiveAire DR85HFA direct-drive centrifugal downblast exhaust fan (Catalog #110C, November 2024; 1658 rpm)
Fan rated 0.90 m³/s at 0.72 kW.
CaptiveAire DU10HFA direct-drive centrifugal upblast exhaust fan (Catalog #110C, November 2024; 1648 rpm)
Fan rated 0.07 m³/s at 0.03 kW.
CaptiveAire DU12HFA direct-drive centrifugal upblast exhaust fan (Catalog #110C, November 2024; 1678 rpm)
Fan rated 0.24 m³/s at 0.16 kW.
CaptiveAire DU180HFA direct-drive centrifugal upblast exhaust fan (Catalog #110C, November 2024; 1722 rpm)
Fan rated 1.65 m³/s at 3.27 kW.
CaptiveAire DU200HFA direct-drive centrifugal upblast exhaust fan (Catalog #110C, November 2024; 1527 rpm)
Fan rated 1.84 m³/s at 3.30 kW.
CaptiveAire DU240HFA direct-drive centrifugal upblast exhaust fan (Catalog #110C, November 2024; 1124 rpm)
Fan rated 2.60 m³/s at 3.77 kW.
CaptiveAire DU300HFA direct-drive centrifugal upblast exhaust fan (Catalog #110C, November 2024; 892 rpm)
Fan rated 3.54 m³/s at 4.54 kW.
CaptiveAire DU30HFA direct-drive centrifugal upblast exhaust fan (Catalog #110C, November 2024; 1744 rpm)
Fan rated 0.35 m³/s at 0.27 kW.
How the model reads against CaptiveAire's data
| Fan power through the fan laws, one curve per fan from a US multi-rating table | 2 813 cells over 57 fans; 49 withheld by name | every held cell's BHP within 2 % plus the half-hundredth it is printed to (the worst at 0.984 of that band; one cell from 0.5 BHP past a bare 2 %, at 2.4 %) and its speed within 0.95 %, read back by the solver's own fan-law solve; RMS 0.41 % on power over the 1 845 cells from 0.5 BHP up. Withheld: 41 cells at the high-static end of a low-flow row, left of the wheel's pressure peak; 6 off the fan laws; 2 printed slips (a 1 in. cell repeating its row's 0 in. figures, a 2.25 in. cell 168 rpm under the 2 in. one). The stainless copies print 71 of their sizes' cells a second time, all within rounding. The SIF9DD and its copy are not listed: their best static efficiency is under 0.2. Each rating lies on its curve (the curve's static at the design flow within 1.00 % of the design static), and the efficiency a listing states is the curves' read there — DU10HFA's best printed cell, 0.02 BHP, would claim 0.383 on input power where its curve reaches 0.353 |
| R454B's saturation line — the properties every R454B map in the catalog runs on — against a maker's printed pressure–temperature table | 40 temperatures × 2 lines, −40 to 155 °F (160–170 °F lie past the top of the backend's R454B line, 71 °C) | one offset, not scatter: at every temperature the backend's dew point is 0.05–0.15 K under the printed one (its dew pressure 0.2–0.5 % over) and its bubble point 0.26–0.33 K under (0.5–1.3 %), so its glide is about 0.2 K wider than the table's. The table does not say whose equation of state it prints, so the offset is held as a bracket on that side, not fitted |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.