1,283 listings in HVAC Builder's catalog from Embraco's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Embraco has not claimed it.
- Compressors — 1,283
Compressor maps by refrigerant: R134a 518, R600a 315, R290 285, R404A 141, R22 11, R1234yf 10, R422D 2, R502 1.
Embraco compressor ranges
Each range on a page of its own: every model code with its refrigerants, frequencies and ratings, and every model a page.
- Embraco EM — 152
- Embraco NT — 78
- Embraco NEK — 77
- Embraco EMT — 76
- Embraco EMY — 65
- Embraco EMX — 63
- Embraco NEU — 62
- Embraco EMI — 43
- Embraco EMC — 42
- Embraco EMU — 32
- Embraco FFU — 32
- Embraco FFI — 29
- Embraco NJ — 28
- Embraco FMFT — 24
- Embraco FF — 20
- Embraco EGAS — 19
- Embraco EMR — 18
- Embraco FFUS — 16
- Embraco EMIE — 15
- Embraco EMZ — 14
- Embraco EGYS — 13
- Embraco EMIS — 13
- Embraco EMYS — 13
- Embraco EGZS — 12
- Embraco NEX — 12
- Embraco NTU — 12
- Embraco VEGT — 12
- Embraco VEMY — 12
- Embraco EGX — 11
- Embraco EMD — 10
- Embraco FFV — 10
- Embraco NTX — 10
- Embraco NE — 9
- Embraco VESA — 9
- Embraco EGUS — 8
- Embraco EHU — 8
- Embraco FGS — 8
- Embraco FMXA — 8
- Embraco FMXY — 8
- Embraco VEMT — 8
- Embraco VESD — 8
- Embraco VNEK — 7
- Embraco EMB — 6
- Embraco FMSA — 6
- Embraco FMSY — 6
- Embraco FMXD — 6
- Embraco NJX — 6
- Embraco VESF — 6
- Embraco VESG — 6
- Embraco VNEX — 6
- Embraco EMYE — 5
- Embraco EG — 4
- Embraco EME — 4
- Embraco EMRS — 4
- Embraco FMXC — 4
- Embraco VEMX — 4
- Embraco VEMZ — 4
- Embraco VESC — 4
- Embraco VESH — 4
- Embraco EGD — 3
- Embraco EGU — 3
- Embraco EGZ — 3
- Embraco EMSS — 3
- Embraco EMTE — 3
- Embraco FFC — 3
- Embraco FG — 3
- Embraco VEG — 3
- Embraco VEGC — 3
- Embraco VEGD — 3
- Embraco VEMC — 3
- Embraco VNEU — 3
- Embraco EHX — 2
- Embraco EMM — 2
- Embraco EMS — 2
- Embraco EMUE — 2
- Embraco EMXS — 2
- Embraco ESC — 2
- Embraco ESU — 2
- Embraco FMFD — 2
- Embraco FMR — 2
- Embraco VEGY — 2
- Embraco VEHT — 2
- Embraco VEHU — 2
Are you Embraco?
Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Components
Showing 625–648 of 1,283
| Name | Type | Rating | Markets | Open in the builder |
|---|---|---|---|---|
| Embraco EMU45HEP (R134a hermetic, LBP, ASHRAE, 50-60 Hz) Catalog | Compressors | R134a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.28 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMX3113U (R290 hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | R290 compressor — 0.20 kW cooling, 0.11 kW input, COP 1.79 at -25/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMY3117U (R290 hermetic, MBP, EN12900, 50 Hz) Catalog | Compressors | R290 compressor — 0.20 kW cooling, 0.12 kW input, COP 1.67 at -25/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMYS80HSP (R134a hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | R134a compressor — 0.16 kW cooling, 0.08 kW input, COP 1.90 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMZ70CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | R600a compressor — 0.15 kW cooling, 0.09 kW input, COP 1.68 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco FF7,5HBK (R134a hermetic, MBP, EN12900, 50-60 Hz) Catalog | Compressors | R134a compressor — 0.54 kW cooling, 0.30 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco FFI12HBK (R134a hermetic, MBP, EN12900, 50 Hz) Catalog | Compressors | R134a compressor — 1.0 kW cooling, 0.50 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco FFU130UAX (R290 hermetic, MBP, EN12900, 50-60 Hz) Catalog | Compressors | R290 compressor — 0.29 kW cooling, 0.20 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco FFUS80HAK (R134a hermetic, LBP, EN12900, 50-60 Hz) Catalog | Compressors | R134a compressor — 0.17 kW cooling, 0.12 kW input, COP 1.36 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco FMFT411U (R290 variable-capacity hermetic, LBP, EN12900) Catalog | Compressors | R290 compressor — 0.64 kW cooling, 0.39 kW input, COP 1.64 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco NEK2125GK (R404A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R404A compressor — 0.17 kW cooling, 0.20 kW input, COP 0.88 at -35/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco NEU2155U (R290 hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | R290 compressor — 0.39 kW cooling, 0.37 kW input, COP 1.07 at -35/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco NJ9226E (R22 hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | R22 compressor — 2.8 kW cooling, 1.13 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco NT2170U (R290 hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | R290 compressor — 0.54 kW cooling, 0.49 kW input, COP 1.10 at -35/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EGAS80HLR (R134a hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | R134a compressor — 0.19 kW cooling, 0.13 kW input, COP 1.48 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EM2C40CLT (R600a hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R600a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.60 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMC3125U (R290 hermetic, LBP, EN12900, 50-60 Hz) Catalog | Compressors | R290 compressor — 0.26 kW cooling, 0.15 kW input, COP 1.70 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMI40CNP (R600a hermetic, LBP, ASHRAE, 50-60 Hz) Catalog | Compressors | R600a compressor — 0.09 kW cooling, 0.08 kW input, COP 1.12 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMIE40HJP (R134a hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | R134a compressor — 0.08 kW cooling, 0.07 kW input, COP 1.08 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMR70HLC (R134a hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R134a compressor — 0.11 kW cooling, 0.10 kW input, COP 1.13 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMT22HLP (R134a hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R134a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.09 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMU45HER (R134a hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | R134a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMX3113U (R290 hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | R290 compressor — 0.20 kW cooling, 0.11 kW input, COP 1.79 at -25/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Embraco EMY3118Y (R600a hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | R600a compressor — 0.16 kW cooling, 0.11 kW input, COP 1.43 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
How the model reads against Embraco's data
| Embraco hermetic and variable-capacity compressor maps, fitted from the maker's published tables | 1 283 maps from 815 models (R134a 518, R600a 315, R290 285, R404A 141, R22 11, R1234yf 10, R422D 2, R502 1); 178 variable-capacity models with a table per speed | fitted at the order each table's levels determine (three condensing levels: quadratic in tc), the tables are reproduced at a median RMS of 0.08 % (p90 0.20 %); every map reads the standard's own rating point within 0.08 % at the median and 0.4 % at the ninetieth percentile; every carried flow set closes the identity once the rating's own return-gas and liquid temperatures are read off the node (ASHRAE rates with the liquid at 32.2 °C, 22 K under the condenser). 72 tables withheld and listed by reason: blend groups published as one table, variable-capacity models with fewer than three speeds tabulated, three with a COP under 0.5 at the rating point, three duplicates |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.