Sigma Unclaimed
112 listing(s) in HVAC Builder's catalog from Sigma's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Sigma has not claimed it.
- Radiators and emitters — 112
Are you Sigma?
Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Listings
Showing 25–48 of 112
Sigma SRK-P-5-CV3-3H-4CC panel radiator (pedestal, CV3-3H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.550 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-5-CV3-4H-3CC panel radiator (pedestal, CV3-4H-3CC coil), per foot
Hydronic emitter rated per foot of active length: 0.556 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-5-E24-1R panel radiator (pedestal, E24 element, 1 row), per foot
Hydronic emitter rated per foot of active length: 0.257 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-5-E24-2R panel radiator (pedestal, E24 element, 2 rows), per foot
Hydronic emitter rated per foot of active length: 0.357 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-CV2-2H-4CC panel radiator (pedestal, CV2-2H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.309 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-CV2-3H-4CC panel radiator (pedestal, CV2-3H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.363 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-CV2-4H-4CC panel radiator (pedestal, CV2-4H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.390 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-CV2-F6 panel radiator (pedestal, CV2-F6 coil), per foot
Hydronic emitter rated per foot of active length: 0.215 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-CV3-2H-4CC panel radiator (pedestal, CV3-2H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.487 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-CV3-3H-4CC panel radiator (pedestal, CV3-3H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.573 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-CV3-4H-4CC panel radiator (pedestal, CV3-4H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.606 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-E24-1R panel radiator (pedestal, E24 element, 1 row), per foot
Hydronic emitter rated per foot of active length: 0.272 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-E24-2R panel radiator (pedestal, E24 element, 2 rows), per foot
Hydronic emitter rated per foot of active length: 0.401 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-P-6-E24-3R panel radiator (pedestal, E24 element, 3 rows), per foot
Hydronic emitter rated per foot of active length: 0.461 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-CV2-2H-4CC panel radiator (wall mount, CV2-2H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.349 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-CV2-3H-4CC panel radiator (wall mount, CV2-3H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.410 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-CV2-4H-4CC panel radiator (wall mount, CV2-4H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.441 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-CV2-F6 panel radiator (wall mount, CV2-F6 coil), per foot
Hydronic emitter rated per foot of active length: 0.243 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-CV3-2H-4CC panel radiator (wall mount, CV3-2H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.550 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-CV3-3H-4CC panel radiator (wall mount, CV3-3H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.647 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-CV3-4H-4CC panel radiator (wall mount, CV3-4H-4CC coil), per foot
Hydronic emitter rated per foot of active length: 0.685 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-E24-1R panel radiator (wall mount, E24 element, 1 row), per foot
Hydronic emitter rated per foot of active length: 0.305 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-E24-2R panel radiator (wall mount, E24 element, 2 rows), per foot
Hydronic emitter rated per foot of active length: 0.424 kW at an excess of 52.8 K, exponent 1.3.
Sigma SRK-W-10-E24-3R panel radiator (wall mount, E24 element, 3 rows), per foot
Hydronic emitter rated per foot of active length: 0.489 kW at an excess of 52.8 K, exponent 1.3.
How the model reads against Sigma's data
| Panel radiators rated per foot, against their maker's own tables: the emitter's power law read from the one column the maker's correction table does not generate, carried to the others by the model's default exponent — none being measured | 784 printed cells; 112 listings | listed at the 160 °F column (52.8 K over 65 °F) with the model's default exponent, 1.3 — Sigma's own correction table, the generator of the other columns, is no power law (read as one it implies 1.19 to 1.47 column by column) — the model reads every printed cell within −3.97 to +1.98 %, through the forward pass at each column's mean water. In a room, as for every rating over 65 °F entering air: a 68–70 °F room reads 4.1–6.8 % under the tested rating at 160 °F, which the listings' pages state |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.