Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsRadiator / emitter 112
All marketsNA 112
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 73–96 of 112

Sigma SRK-W-6-CV2-2H-4CC panel radiator (wall mount, CV2-2H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.309 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-6-CV2-3H-4CC panel radiator (wall mount, CV2-3H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.363 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-6-CV2-4H-4CC panel radiator (wall mount, CV2-4H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.390 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-6-CV2-F6 panel radiator (wall mount, CV2-F6 coil), per foot

Hydronic emitter rated per foot of active length: 0.215 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-6-CV3-2H-4CC panel radiator (wall mount, CV3-2H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.487 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-6-CV3-3H-4CC panel radiator (wall mount, CV3-3H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.573 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-6-CV3-4H-4CC panel radiator (wall mount, CV3-4H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.606 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-6-E24-1R panel radiator (wall mount, E24 element, 1 row), per foot

Hydronic emitter rated per foot of active length: 0.270 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-6-E24-2R panel radiator (wall mount, E24 element, 2 rows), per foot

Hydronic emitter rated per foot of active length: 0.368 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-6-E24-3R panel radiator (wall mount, E24 element, 3 rows), per foot

Hydronic emitter rated per foot of active length: 0.423 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-CV2-2H-4CC panel radiator (wall mount, CV2-2H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.320 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-CV2-3H-4CC panel radiator (wall mount, CV2-3H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.376 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-CV2-4H-4CC panel radiator (wall mount, CV2-4H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.404 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-CV2-F6 panel radiator (wall mount, CV2-F6 coil), per foot

Hydronic emitter rated per foot of active length: 0.223 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-CV3-2H-4CC panel radiator (wall mount, CV3-2H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.504 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-CV3-3H-4CC panel radiator (wall mount, CV3-3H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.593 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-CV3-4H-4CC panel radiator (wall mount, CV3-4H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.627 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-E24-1R panel radiator (wall mount, E24 element, 1 row), per foot

Hydronic emitter rated per foot of active length: 0.280 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-E24-2R panel radiator (wall mount, E24 element, 2 rows), per foot

Hydronic emitter rated per foot of active length: 0.382 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-7-E24-3R panel radiator (wall mount, E24 element, 3 rows), per foot

Hydronic emitter rated per foot of active length: 0.440 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-8-CV2-2H-4CC panel radiator (wall mount, CV2-2H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.329 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-8-CV2-3H-4CC panel radiator (wall mount, CV2-3H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.387 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-8-CV2-4H-4CC panel radiator (wall mount, CV2-4H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.416 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-8-CV2-F6 panel radiator (wall mount, CV2-F6 coil), per foot

Hydronic emitter rated per foot of active length: 0.229 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA
‹ Previous12345Next ›

How the model reads against Sigma's data

Panel radiators rated per foot, against their maker's own tables: the emitter's power law read from the one column the maker's correction table does not generate, carried to the others by the model's default exponent — none being measured784 printed cells; 112 listingslisted at the 160 °F column (52.8 K over 65 °F) with the model's default exponent, 1.3 — Sigma's own correction table, the generator of the other columns, is no power law (read as one it implies 1.19 to 1.47 column by column) — the model reads every printed cell within −3.97 to +1.98 %, through the forward pass at each column's mean water. In a room, as for every rating over 65 °F entering air: a 68–70 °F room reads 4.1–6.8 % under the tested rating at 160 °F, which the listings' pages state

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.