Sigma Unclaimed

112 listing(s) in HVAC Builder's catalog from Sigma's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Sigma has not claimed it.

Are you Sigma?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsRadiator / emitter 112
All marketsNA 112
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 49–72 of 112

Sigma SRK-W-2-CV2-2H-2CC panel radiator (wall mount, CV2-2H-2CC coil), per foot

Hydronic emitter rated per foot of active length: 0.237 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-2-CV2-F6 panel radiator (wall mount, CV2-F6 coil), per foot

Hydronic emitter rated per foot of active length: 0.181 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-2-CV3-2H-2CC panel radiator (wall mount, CV3-2H-2CC coil), per foot

Hydronic emitter rated per foot of active length: 0.373 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-2-E24-1R panel radiator (wall mount, E24 element, 1 row), per foot

Hydronic emitter rated per foot of active length: 0.227 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-3-CV2-2H-2CC panel radiator (wall mount, CV2-2H-2CC coil), per foot

Hydronic emitter rated per foot of active length: 0.248 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-3-CV2-F6 panel radiator (wall mount, CV2-F6 coil), per foot

Hydronic emitter rated per foot of active length: 0.190 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-3-CV3-2H-2CC panel radiator (wall mount, CV3-2H-2CC coil), per foot

Hydronic emitter rated per foot of active length: 0.390 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-3-E24-1R panel radiator (wall mount, E24 element, 1 row), per foot

Hydronic emitter rated per foot of active length: 0.238 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-4-CV2-2H-4CC panel radiator (wall mount, CV2-2H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.285 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-4-CV2-3H-3CC panel radiator (wall mount, CV2-3H-3CC coil), per foot

Hydronic emitter rated per foot of active length: 0.320 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-4-CV2-F6 panel radiator (wall mount, CV2-F6 coil), per foot

Hydronic emitter rated per foot of active length: 0.198 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-4-CV3-2H-4CC panel radiator (wall mount, CV3-2H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.448 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-4-CV3-3H-3CC panel radiator (wall mount, CV3-3H-3CC coil), per foot

Hydronic emitter rated per foot of active length: 0.504 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-4-E24-1R panel radiator (wall mount, E24 element, 1 row), per foot

Hydronic emitter rated per foot of active length: 0.249 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-4-E24-2R panel radiator (wall mount, E24 element, 2 rows), per foot

Hydronic emitter rated per foot of active length: 0.340 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-5-CV2-2H-4CC panel radiator (wall mount, CV2-2H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.296 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-5-CV2-3H-4CC panel radiator (wall mount, CV2-3H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.349 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-5-CV2-4H-3CC panel radiator (wall mount, CV2-4H-3CC coil), per foot

Hydronic emitter rated per foot of active length: 0.358 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-5-CV2-F6 panel radiator (wall mount, CV2-F6 coil), per foot

Hydronic emitter rated per foot of active length: 0.207 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-5-CV3-2H-4CC panel radiator (wall mount, CV3-2H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.468 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-5-CV3-3H-4CC panel radiator (wall mount, CV3-3H-4CC coil), per foot

Hydronic emitter rated per foot of active length: 0.550 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-5-CV3-4H-3CC panel radiator (wall mount, CV3-4H-3CC coil), per foot

Hydronic emitter rated per foot of active length: 0.556 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-5-E24-1R panel radiator (wall mount, E24 element, 1 row), per foot

Hydronic emitter rated per foot of active length: 0.260 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA

Sigma SRK-W-5-E24-2R panel radiator (wall mount, E24 element, 2 rows), per foot

Hydronic emitter rated per foot of active length: 0.354 kW at an excess of 52.8 K, exponent 1.3.

catalog
Radiator / emitter · NA
‹ Previous12345Next ›

How the model reads against Sigma's data

Panel radiators rated per foot, against their maker's own tables: the emitter's power law read from the one column the maker's correction table does not generate, carried to the others by the model's default exponent — none being measured784 printed cells; 112 listingslisted at the 160 °F column (52.8 K over 65 °F) with the model's default exponent, 1.3 — Sigma's own correction table, the generator of the other columns, is no power law (read as one it implies 1.19 to 1.47 column by column) — the model reads every printed cell within −3.97 to +1.98 %, through the forward pass at each column's mean water. In a room, as for every rating over 65 °F entering air: a 68–70 °F room reads 4.1–6.8 % under the tested rating at 160 °F, which the listings' pages state

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.