Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.
The builder models these: pick one into a design and it solves on the listing's figures.
Showing 4,849–4,872 of 14,438
| Name | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|
| Tecumseh FH4522P-XG1A (R454C hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R454C compressor — 4.4 kW cooling, 1.56 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland YA182K1E-TF7 (R454B scroll, 60 Hz, AC) Catalog | Copeland | R454B compressor — 54.4 kW cooling, 16.55 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss MLZ015T2C (R448A scroll, 50 Hz, MT) Catalog | Danfoss | R448A compressor — 5.5 kW cooling, 2.13 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NEK6144Y (R600a hermetic, HBP, EN12900, 50 Hz) Catalog | Embraco | R600a compressor — 0.49 kW cooling, 0.23 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF45E1G-Q100 (R404A low-temperature freezing scroll, 60 Hz, 460 V 3P) Catalog | Invotech | R404A compressor — 6.1 kW cooling, 4.59 kW input, COP 1.32 at -30/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Tecumseh AE4430Y-FZ1A (R134a hermetic, HBP, ASHRAE, 50 Hz) Catalog | Tecumseh | R134a compressor — 0.82 kW cooling, 0.34 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland YAD147K1E-TE5 (R454B scroll, 60 Hz, AC) Catalog | Copeland | R454B compressor — 43.0 kW cooling, 13.26 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss MT040-3 (R22 hermetic reciprocating, 60 Hz, A/C) Catalog | Danfoss | R22 compressor — 12.6 kW cooling, 4.63 kW input, COP 2.72 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NEU6210E (R422D hermetic, HBP, EN12900, 50 Hz) Catalog | Embraco | R422D compressor — 1.0 kW cooling, 0.54 kW input, COP 1.87 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH355C7-100 (R410A air-conditioning scroll, 60 Hz, 220 V 3P) Catalog | Invotech | R410A compressor — 42.2 kW cooling, 13.10 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AG2525Z-KZ1A (R448A hermetic, LBP, EN12900, 60 Hz) Catalog | Tecumseh | R448A compressor — 3.6 kW cooling, 3.41 kW input, COP 1.06 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland YADU24P1E-TF5 (R454B scroll, 50 Hz, AC) Catalog | Copeland | R454B compressor — 56.6 kW cooling, 17.93 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss MTZ018-4 (R452A hermetic reciprocating, 60 Hz, MT) Catalog | Danfoss | R452A compressor — 4.4 kW cooling, 2.04 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NT2212GKV (R404A hermetic, LBP, EN12900, 50 Hz) Catalog | Embraco | R404A compressor — 0.74 kW cooling, 0.67 kW input, COP 1.10 at -35/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM70A8G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 575 V 3P) Catalog | Invotech | R22 compressor — 13.5 kW cooling, 4.61 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AGB4573ZTZ (R404A hermetic, HBP, EN12900, 60 Hz) Catalog | Tecumseh | R404A compressor — 17.8 kW cooling, 8.57 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland YASU16M1E-TF5 (R454B scroll, 50 Hz, AC) Catalog | Copeland | R454B compressor — 41.2 kW cooling, 12.03 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss NTZ068-4B (R455A hermetic reciprocating, 50 Hz, LT) Catalog | Danfoss | R455A compressor — 2.0 kW cooling, 1.47 kW input, COP 1.34 at -30/35 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Embraco EM2U3115U (R290 hermetic, LBP, EN12900, 60 Hz) Catalog | Embraco | R290 compressor — 0.17 kW cooling, 0.12 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF45E1G-Q100 (R448A low-temperature freezing scroll, 50 Hz, 380 V 3P) Catalog | Invotech | R448A compressor — 4.6 kW cooling, 3.90 kW input, COP 1.18 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AJ2446Z-XA3C (R452A hermetic, LBP, EN12900, 60 Hz) Catalog | Tecumseh | R452A compressor — 0.58 kW cooling, 0.66 kW input, COP 0.88 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland YAT108K1E-TFD (R454B scroll, 60 Hz, AC) Catalog | Copeland | R454B compressor — 32.0 kW cooling, 9.89 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss PSH026-3E (R410A scroll, 60 Hz) Catalog | Danfoss | R410A compressor — 34.7 kW cooling, 11.72 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMC60CLT (R600a hermetic, LBP, EN12900, 50 Hz) Catalog | Embraco | R600a compressor — 0.12 kW cooling, 0.07 kW input, COP 1.67 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |