All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 45Systems 3,474Components 15,410Accessories 0

Showing 5,761–5,784 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland CS10KIE-PFV (R404A hermetic recip, 60 Hz, MT) CatalogCopelandR404A compressor — 1.7 kW cooling, 1.13 kW input, COP 1.48 at -20/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM045U4 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 13.2 kW cooling, 4.01 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY80HLC (R134a hermetic, LBP, EN12900, 50 Hz) CatalogEmbracoR134a compressor — 0.14 kW cooling, 0.10 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464U-HZ3C (R290 hermetic, LBP, EN12900, 60 Hz) CatalogTecumsehR290 compressor — 0.88 kW cooling, 0.86 kW input, COP 1.02 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland KCE432HAG-SXH (R134A hermetic recip, 50 Hz, HT) CatalogCopelandR134a compressor — 0.79 kW cooling, 0.37 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss HRP054T2 (R407C scroll, 60 Hz, A/C) CatalogDanfossR407C compressor — 15.2 kW cooling, 4.73 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6210Z (R134a hermetic, HBP, EN12900, 50 Hz) CatalogEmbracoR134a compressor — 1.1 kW cooling, 0.60 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4522Z-XN3A (R452A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR452A compressor — 4.7 kW cooling, 2.04 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland KCJ450LAL-B3H (R404A hermetic recip, 50 Hz, LT) CatalogCopelandR404A compressor — 0.45 kW cooling, 0.54 kW input, COP 0.84 at -35/50 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Danfoss LLZ015T2A (R449A scroll, 60 Hz, LT) CatalogDanfossR449A compressor — 3.8 kW cooling, 2.85 kW input, COP 1.32 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco NT6222GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogEmbracoR404A compressor — 2.7 kW cooling, 1.31 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4440Z-FZ1A (R449A hermetic, HBP, ASHRAE, 50 Hz) CatalogTecumsehR449A compressor — 1.0 kW cooling, 0.42 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland KCM514CAL-B3H (R404A hermetic recip, 50 Hz, MT) CatalogCopelandR404A compressor — 6.4 kW cooling, 2.45 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss MLZ015T2C (R455A scroll, 60 Hz) CatalogDanfossR455A compressor — 6.3 kW cooling, 2.26 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X3113U (R290 hermetic, MBP, EN12900, 50 Hz) CatalogEmbracoR290 compressor — 0.13 kW cooling, 0.08 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4546P-TZ1A (R448A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR448A compressor — 9.9 kW cooling, 4.07 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland KCN413CAG-V3H (R134A hermetic recip, 60 Hz, MT) CatalogCopelandR134a compressor — 0.65 kW cooling, 0.26 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss MT050-4 (R22 hermetic reciprocating, 50 Hz, MT) CatalogDanfossR22 compressor — 11.3 kW cooling, 4.19 kW input, COP 2.71 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT6152U (R290 hermetic, MBP, EN12900, 50 Hz) CatalogEmbracoR290 compressor — 0.65 kW cooling, 0.28 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB5561ETZ (R22 hermetic, AC, Tecumseh Europe, 50 Hz) CatalogTecumsehR22 compressor — 14.9 kW cooling, 5.26 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland RFT22C1E-IAV (R448A hermetic recip, 60 Hz, LT) CatalogCopelandR448A compressor — 0.42 kW cooling, 0.43 kW input, COP 0.96 at -30/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ018-5 (R407A hermetic reciprocating, 50 Hz, MT) CatalogDanfossR407A compressor — 3.6 kW cooling, 1.56 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6210Z (R134a hermetic, HBP, EN12900, 60 Hz) CatalogEmbracoR134a compressor — 1.2 kW cooling, 0.61 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464U-XA3C (R290 hermetic, LBP, EN12900, 50 Hz) CatalogTecumsehR290 compressor — 0.72 kW cooling, 0.72 kW input, COP 1.01 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
‹ Previous1…239240241242243…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors