All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 45Systems 3,474Components 15,410Accessories 0

Showing 5,737–5,760 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland AFF10C1E-IA3 (R134A hermetic recip, 60 Hz, EF) CatalogCopelandR134a compressor — 0.34 kW cooling, 0.25 kW input, COP 1.34 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss VZH052CH (R410A inverter scroll, A/C) CatalogDanfossR410A compressor — 27.4 kW cooling, 9.39 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT6144Z (R134a hermetic, HBP, EN12900, 50 Hz) CatalogEmbracoR134a compressor — 0.52 kW cooling, 0.22 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB5561ECZ (R22 hermetic, AC, Tecumseh Europe, 60 Hz) CatalogTecumsehR22 compressor — 17.5 kW cooling, 6.65 kW input, COP 2.64 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ARE17C4E-IAA (R450A hermetic recip, 60 Hz, HT) CatalogCopelandR450A compressor — 0.47 kW cooling, 0.26 kW input, COP 1.83 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss DCJ121T4A (R454B scroll, 50 Hz) CatalogDanfossR454B compressor — 25.4 kW cooling, 8.58 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY80CLP (R600a hermetic, LBP, EN12900, 50 Hz) CatalogEmbracoR600a compressor — 0.15 kW cooling, 0.10 kW input, COP 1.42 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464U-FZ3C (R290 hermetic, LBP, EN12900, 50 Hz) CatalogTecumsehR290 compressor — 0.73 kW cooling, 0.72 kW input, COP 1.01 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ASE14C4E-IAA (R404A hermetic recip, 60 Hz, MT) CatalogCopelandR404A compressor — 0.30 kW cooling, 0.30 kW input, COP 1.01 at -20/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSF530-3 (R32 scroll, 60 Hz, HT) CatalogDanfossR32 compressor — 156.3 kW cooling, 45.56 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6210U (R290 hermetic, MBP, EN12900, 60 Hz) CatalogEmbracoR290 compressor — 1.1 kW cooling, 0.57 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4522Z-XN3A (R449A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR449A compressor — 5.6 kW cooling, 2.23 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ASM16C1U-RAA (R290 hermetic recip, 60 Hz, EM) CatalogCopelandR290 compressor — 0.26 kW cooling, 0.15 kW input, COP 1.68 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH140-4 (R452B scroll, 50 Hz, HT) CatalogDanfossR452B compressor — 30.4 kW cooling, 10.31 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT6222GK (R404A hermetic, MBP, EN12900, 50 Hz) CatalogEmbracoR404A compressor — 2.1 kW cooling, 1.19 kW input, COP 1.72 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4440Z-FZ1A (R448A hermetic, HBP, ASHRAE, 50 Hz) CatalogTecumsehR448A compressor — 1.0 kW cooling, 0.42 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland CF09K7ME-TFD (R404A hermetic recip, 50 Hz, LT) CatalogCopelandR404A compressor — 2.0 kW cooling, 1.58 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HLJ083T4A (R410A scroll, 50 Hz) CatalogDanfossR410A compressor — 18.2 kW cooling, 6.27 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X3113U (R290 hermetic, LBP, EN12900, 60 Hz) CatalogEmbracoR290 compressor — 0.16 kW cooling, 0.10 kW input, COP 1.63 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4546P-TZ1A (R404A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR404A compressor — 11.4 kW cooling, 5.58 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland CR17K9M-PFV (R22 hermetic recip, 60 Hz, HT) CatalogCopelandR22 compressor — 4.9 kW cooling, 1.52 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HRH034U4 (R410A scroll, 50 Hz, A/C) CatalogDanfossR410A compressor — 8.5 kW cooling, 2.90 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT6152GK (R404A hermetic, MBP, EN12900, 50 Hz) CatalogEmbracoR404A compressor — 0.62 kW cooling, 0.33 kW input, COP 1.88 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB5561EKZ (R22 hermetic, AC, Tecumseh Europe, 50 Hz) CatalogTecumsehR22 compressor — 14.9 kW cooling, 5.08 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
‹ Previous1…238239240241242…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors