All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 1,009–1,032 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Tecumseh AWA7515ZXD (R449A hermetic, HBP, ARI, 60 Hz) CatalogTecumsehR449A compressor — 3.7 kW cooling, 2.13 kW input, COP 1.72 at -15/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland CREQ-022E-TF5 (R407C hermetic recip, 50 Hz, AC) CatalogCopelandR407C compressor — 6.1 kW cooling, 2.10 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MTZ018-1 (R448A hermetic reciprocating, 60 Hz, MT) CatalogDanfossR448A compressor — 4.3 kW cooling, 1.88 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMR100HLC (R134a hermetic, MBP, EN12900, 50-60 Hz) CatalogEmbracoR134a compressor — 0.19 kW cooling, 0.14 kW input, COP 1.43 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF75A4G-V100 (R22 low-temperature freezing scroll, 60 Hz, 460 V 3P) CatalogInvotechR22 compressor — 29.7 kW cooling, 11.44 kW input, COP 2.59 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AWS2512ZXC (R404A hermetic, LBP, ASHRAE, 50 Hz) CatalogTecumsehR404A compressor — 1.9 kW cooling, 1.47 kW input, COP 1.30 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland CRGQ-025E-TF5 (R407C hermetic recip, 50 Hz, AC) CatalogCopelandR407C compressor — 7.2 kW cooling, 2.46 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss NTZ048-3B (R404A hermetic reciprocating, 60 Hz, LT) CatalogDanfossR404A compressor — 0.61 kW cooling, 0.71 kW input, COP 0.87 at -40/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EMRS40CLP (R600a hermetic, LBP, EN12900, 50 Hz) CatalogEmbracoR600a compressor — 0.09 kW cooling, 0.06 kW input, COP 1.51 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW135A1-100 (R22 heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogInvotechR22 compressor — 17.9 kW cooling, 5.53 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh FH2480P-XG1A (R404A hermetic, LBP, EN12900, 60 Hz) CatalogTecumsehR404A compressor — 1.1 kW cooling, 1.11 kW input, COP 0.96 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland CRTQ-045E-TF5 (R22 hermetic recip, 60 Hz, AC) CatalogCopelandR22 compressor — 15.0 kW cooling, 5.09 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss PSH019-4 (R410A scroll, 50 Hz) CatalogDanfossR410A compressor — 21.3 kW cooling, 7.52 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMSS66CLC (R600a hermetic, LBP, EN12900, 50 Hz) CatalogEmbracoR600a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF13E5G-V100 (R404A low-temperature freezing scroll, 60 Hz, 380 V 3P) CatalogInvotechR404A compressor — 2.2 kW cooling, 1.84 kW input, COP 1.19 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh HG5460N-FZ4A (R1234yf hermetic, AC, EN12900, 50 Hz) CatalogTecumsehR1234yf compressor — 1.2 kW cooling, 0.47 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland CS07KQE-TF5 (R404A hermetic recip, 60 Hz, MT) CatalogCopelandR404A compressor — 1.3 kW cooling, 0.95 kW input, COP 1.37 at -20/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SH090-7 (R410A scroll, 60 Hz, A/C) CatalogDanfossR410A compressor — 27.1 kW cooling, 8.57 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT1121U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogEmbracoR290 compressor — 0.17 kW cooling, 0.15 kW input, COP 1.14 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH119C6-100 (R410A air-conditioning scroll, 50 Hz, 220 V 3P) CatalogInvotechR410A compressor — 12.0 kW cooling, 3.92 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh RGA5492EXA (R22 hermetic, AC, EN12900, 60 Hz) CatalogTecumsehR22 compressor — 2.5 kW cooling, 0.84 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland FW49KWT-TFM (R32 scroll, 50 Hz, HP) CatalogCopelandR32 compressor — 12.0 kW cooling, 3.80 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss SM090-6 (R22 scroll, 50 Hz, A/C) CatalogDanfossR22 compressor — 21.8 kW cooling, 6.54 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMTE6187Z (R134a hermetic, HBP, EN12900, 50 Hz) CatalogEmbracoR134a compressor — 0.85 kW cooling, 0.37 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
‹ Previous1…4142434445…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors