Compressors
Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.
The builder models these: pick one into a design and it solves on the listing's figures.
Showing 1,585–1,608 of 14,438
| Name | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|
| Copeland 3DBDR12ME-TFC (R407C Discus recip, 60 Hz, MD) Catalog | Copeland | R407C compressor — 19.9 kW cooling, 7.28 kW input, COP 2.73 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MT019-5 (R22 hermetic reciprocating, 50 Hz, MT) Catalog | Danfoss | R22 compressor — 3.9 kW cooling, 1.45 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EGYS70HLP (R134a hermetic, LBP, ASHRAE, 60 Hz) Catalog | Embraco | R134a compressor — 0.16 kW cooling, 0.10 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YW155J7-100 (R134a heat-pump water heater scroll, 60 Hz, 220 V 3P) Catalog | Invotech | R134a compressor — 17.3 kW cooling, 5.29 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AJ2432P-FZ3A (R449A hermetic, LBP, EN12900, 50 Hz) Catalog | Tecumseh | R449A compressor — 0.40 kW cooling, 0.41 kW input, COP 0.97 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 3DEHR10ME-TFD (R407C Discus recip, 60 Hz, MD) Catalog | Copeland | R407C compressor — 16.5 kW cooling, 6.14 kW input, COP 2.69 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ018-1 (R454C hermetic reciprocating, 60 Hz) Catalog | Danfoss | R454C compressor — 4.2 kW cooling, 1.73 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EGZS70HLC (R134a hermetic, LBP, ASHRAE, 50-60 Hz) Catalog | Embraco | R134a compressor — 0.16 kW cooling, 0.10 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF17E1G-V100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P) Catalog | Invotech | R404A compressor — 2.3 kW cooling, 1.93 kW input, COP 1.20 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AJK480Z-TZ1C (R448A hermetic, HBP, EN12900, 60 Hz) Catalog | Tecumseh | R448A compressor — 2.3 kW cooling, 1.12 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 3DF3F40KE-TFD (R407C Discus recip, 50 Hz, LT) Catalog | Copeland | R407C compressor — 6.9 kW cooling, 5.31 kW input, COP 1.30 at -35/40 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss NTZ048-4B (R404A hermetic reciprocating, 50 Hz, LT) Catalog | Danfoss | R404A compressor — 0.51 kW cooling, 0.59 kW input, COP 0.88 at -40/45 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Embraco EHU2155U (R290 hermetic, LBP, EN12900, 50 Hz) Catalog | Embraco | R290 compressor — 0.34 kW cooling, 0.27 kW input, COP 1.26 at -35/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH128C5-100 (R410A air-conditioning scroll, 60 Hz, 380 V 3P) Catalog | Invotech | R410A compressor — 15.5 kW cooling, 5.06 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AKA9462ZXA (R404A hermetic, HBP, ARI, 60 Hz) Catalog | Tecumseh | R404A compressor — 3.0 kW cooling, 1.70 kW input, COP 1.78 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 3DFDF40KE-TFD (R407A Discus recip, 60 Hz, LD) Catalog | Copeland | R407A compressor — 9.8 kW cooling, 5.54 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss PSH019-4E (R454B scroll, 50 Hz) Catalog | Danfoss | R454B compressor — 20.2 kW cooling, 7.21 kW input, COP 2.80 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM20HHP (R134a hermetic, MBP, EN12900, 60 Hz) Catalog | Embraco | R134a compressor — 0.24 kW cooling, 0.12 kW input, COP 1.96 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM132E7G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 220 V 3P) Catalog | Invotech | R404A compressor — 24.6 kW cooling, 9.46 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AL4510Z-FZ3B (R404A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R404A compressor — 2.2 kW cooling, 1.10 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 3DFDR15ME-TFD (R407C Discus recip, 60 Hz, AC) Catalog | Copeland | R407C compressor — 47.8 kW cooling, 15.13 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss SH105-4 (R410A scroll, 60 Hz, A/C) Catalog | Danfoss | R410A compressor — 32.1 kW cooling, 9.96 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMB55CLC (R600a hermetic, LBP, EN12900, 50 Hz) Catalog | Embraco | R600a compressor — 0.11 kW cooling, 0.07 kW input, COP 1.66 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YW155J8-100 (R134a heat-pump water heater scroll, 60 Hz, 575 V 3P) Catalog | Invotech | R134a compressor — 17.3 kW cooling, 5.29 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors