All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 1,681–1,704 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Danfoss HLM072T7 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 21.3 kW cooling, 6.47 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFI10HBX (R134a hermetic, HBP, EN12900, 60 Hz) CatalogEmbracoR134a compressor — 1.0 kW cooling, 0.46 kW input, COP 2.22 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM158A5G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 380 V 3P) CatalogInvotechR22 compressor — 31.2 kW cooling, 10.34 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AWS4522EXN (R22 hermetic, HBP, ASHRAE, 50 Hz) CatalogTecumsehR22 compressor — 5.6 kW cooling, 1.95 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3YB3R11ME-TFC (R454C Discus recip, 60 Hz, MD) CatalogCopelandR454C compressor — 18.9 kW cooling, 6.81 kW input, COP 2.77 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLP072T7 (R407C scroll, 60 Hz, A/C) CatalogDanfossR407C compressor — 19.9 kW cooling, 6.24 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFU130HAX (R134a hermetic, LBP, ASHRAE, 50 Hz) CatalogEmbracoR134a compressor — 0.25 kW cooling, 0.17 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW160A7-100 (R22 heat-pump water heater scroll, 60 Hz, 220 V 3P) CatalogInvotechR22 compressor — 21.1 kW cooling, 6.54 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh FH2480P-XN3A (R455A hermetic, LBP, EN12900, 60 Hz) CatalogTecumsehR455A compressor — 1.3 kW cooling, 1.13 kW input, COP 1.12 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3YBDR11ME-TFC (R454C Discus recip, 60 Hz, MD) CatalogCopelandR454C compressor — 18.9 kW cooling, 6.81 kW input, COP 2.77 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH029U4 (R410A scroll, 60 Hz, A/C) CatalogDanfossR410A compressor — 8.5 kW cooling, 2.84 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFUS100HAX (R134a hermetic, LBP, EN12900, 60 Hz) CatalogEmbracoR134a compressor — 0.21 kW cooling, 0.16 kW input, COP 1.30 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF17E2G-Q102 (R404A low-temperature freezing scroll, 50 Hz, 220 V 1P) CatalogInvotechR404A compressor — 1.9 kW cooling, 1.76 kW input, COP 1.06 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh TC4419Y-UZ1B (R134a hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR134a compressor — 0.48 kW cooling, 0.24 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3YF3R14ME-TFC (R454C Discus recip, 60 Hz, MD) CatalogCopelandR454C compressor — 22.5 kW cooling, 8.18 kW input, COP 2.75 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM034T4 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 10.0 kW cooling, 2.98 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFV7,5HAK (R134a hermetic, MBP, EN12900, 50-60 Hz) CatalogEmbracoR134a compressor — 0.15 kW cooling, 0.12 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH128T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P) CatalogInvotechR407C compressor — 14.8 kW cooling, 4.53 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh TCW390U-GS8E (R290 hermetic, LBP, EN12900, 60 Hz) CatalogTecumsehR290 compressor — 0.25 kW cooling, 0.15 kW input, COP 1.63 at -25/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3YFDR14ME-TFC (R454C Discus recip, 60 Hz, MD) CatalogCopelandR454C compressor — 22.5 kW cooling, 8.18 kW input, COP 2.75 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRP034T4 (R407C scroll, 50 Hz, A/C) CatalogDanfossR407C compressor — 7.9 kW cooling, 2.68 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FGS50CA (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogEmbracoR600a compressor — 0.07 kW cooling, 0.07 kW input, COP 1.08 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM158A6G-100 (R22 medium-temperature refrigeration scroll, 50 Hz, 220 V 3P) CatalogInvotechR22 compressor — 25.9 kW cooling, 8.60 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh THB4419YWZ (R134a hermetic, HBP, ASHRAE, 60 Hz) CatalogTecumsehR134a compressor — 0.54 kW cooling, 0.27 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
‹ Previous1…6970717273…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors