All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 1,729–1,752 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Tecumseh AJ2432P-FZ3A (R454C hermetic, LBP, EN12900, 50 Hz) CatalogTecumsehR454C compressor — 0.32 kW cooling, 0.35 kW input, COP 0.89 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DANF47KE-TSK (R407A Discus recip, 60 Hz, LD) CatalogCopelandR407A compressor — 11.0 kW cooling, 6.43 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss NTZ048-4B (R404A hermetic reciprocating, 60 Hz, LT) CatalogDanfossR404A compressor — 0.61 kW cooling, 0.71 kW input, COP 0.87 at -40/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco FMXY9C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogEmbracoR600a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.55 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF17E3G-Q100 (R404A low-temperature freezing scroll, 60 Hz, 220 V 1P) CatalogInvotechR404A compressor — 2.2 kW cooling, 2.12 kW input, COP 1.06 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AJK480Z-TZ1C (R449A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR449A compressor — 2.3 kW cooling, 1.12 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DANR18ME-TSK (R407A Discus recip, 60 Hz, MD) CatalogCopelandR407A compressor — 30.1 kW cooling, 10.71 kW input, COP 2.81 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH019-4E (R454B scroll, 60 Hz) CatalogDanfossR454B compressor — 24.7 kW cooling, 8.45 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NE2130Z (R134a hermetic, LBP, ASHRAE, 50 Hz) CatalogEmbracoR134a compressor — 0.33 kW cooling, 0.24 kW input, COP 1.39 at -25/45 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH128T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P) CatalogInvotechR407C compressor — 14.8 kW cooling, 4.68 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AKA9462ZXA (R449A hermetic, HBP, ARI, 60 Hz) CatalogTecumsehR449A compressor — 2.6 kW cooling, 1.61 kW input, COP 1.62 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DAXF47KE-TSK (R407A Discus recip, 60 Hz, LD) CatalogCopelandR407A compressor — 11.0 kW cooling, 6.43 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SH105-6 (R410A scroll, 50 Hz, A/C) CatalogDanfossR410A compressor — 23.9 kW cooling, 8.47 kW input, COP 2.82 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK1150U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogEmbracoR290 compressor — 0.33 kW cooling, 0.33 kW input, COP 0.98 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM158E1G-100 (R404A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogInvotechR404A compressor — 25.1 kW cooling, 9.67 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AL4510Z-FZ3B (R449A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR449A compressor — 2.2 kW cooling, 1.02 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DAXR18ME-TSK (R407A Discus recip, 60 Hz, AC) CatalogCopelandR407A compressor — 62.7 kW cooling, 19.40 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SM100-9 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 27.5 kW cooling, 8.14 kW input, COP 3.38 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEU2140U (R290 hermetic, LBP, EN12900, 50-60 Hz) CatalogEmbracoR290 compressor — 0.34 kW cooling, 0.27 kW input, COP 1.25 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW160C5-100 (R410A heat-pump water heater scroll, 60 Hz, 380 V 3P) CatalogInvotechR410A compressor — 21.3 kW cooling, 7.12 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AWA9514ZXN (R452A hermetic, HBP, ARI, 60 Hz) CatalogTecumsehR452A compressor — 6.6 kW cooling, 2.90 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DBNF54KE-TSK (R407F Discus recip, 60 Hz, LD) CatalogCopelandR407F compressor — 12.1 kW cooling, 7.02 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SY300-3 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 94.5 kW cooling, 27.52 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEX4160UA (R290 hermetic, MBP, EN12900, 60 Hz) CatalogEmbracoR290 compressor — 0.57 kW cooling, 0.41 kW input, COP 1.42 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
‹ Previous1…7172737475…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors