Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 2,377–2,400 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Copeland ZPSU11MXE-TFD (R410A scroll, 50 Hz, AC) Catalog | Compressors | Copeland | R410A compressor — 27.3 kW cooling, 8.87 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss HLP072T4 (R407C scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R407C compressor — 20.1 kW cooling, 6.31 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FFUS100HAK (R134a hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.21 kW cooling, 0.15 kW input, COP 1.33 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YSF90A4G-V100 (R22 low-temperature freezing scroll, 60 Hz, 460 V 3P) Catalog | Compressors | Invotech | R22 compressor — 38.6 kW cooling, 14.72 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh TC4415Y-UZ1B (R513A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R513A compressor — 0.47 kW cooling, 0.23 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ZPV0212E-2E9 (R410A variable-speed scroll, 3 steps) Catalog | Compressors | Copeland | R410A compressor — 8.8 kW cooling, 2.98 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Danfoss HRH029U2A (R454B scroll, 60 Hz) Catalog | Compressors | Danfoss | R454B compressor — 7.9 kW cooling, 2.86 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FFV7,5HAK (R134a hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.16 kW cooling, 0.12 kW input, COP 1.39 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YW140J7-100 (R134a heat-pump water heater scroll, 60 Hz, 220 V 3P) Catalog | Compressors | Invotech | R134a compressor — 16.0 kW cooling, 4.94 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh TCW380U-GS8A (R290 hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R290 compressor — 0.23 kW cooling, 0.15 kW input, COP 1.52 at -25/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland ZPVU238ZE-5M5 (R410A scroll, 60 Hz, AC) Catalog | Compressors | Copeland | R410A compressor — 76.4 kW cooling, 23.87 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss HRM032U4 (R22 scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 9.3 kW cooling, 2.94 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FGS125HAS (R134a hermetic, MBP, EN12900, 50-60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.34 kW cooling, 0.24 kW input, COP 1.41 at -25/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF17A7G-Q100 (R22 low-temperature freezing scroll, 60 Hz, 220 V 3P) Catalog | Compressors | Invotech | R22 compressor — 2.2 kW cooling, 1.88 kW input, COP 1.17 at -30/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Tecumseh THB4415YXA (R134a hermetic, HBP, ASHRAE, 60 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 0.45 kW cooling, 0.22 kW input, COP 2.03 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ZPW0802E-4X9 (R410A variable-speed scroll) Catalog | Compressors | Copeland | R410A compressor — 40.4 kW cooling, 12.06 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Danfoss HRP034T2 (R407C scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R407C compressor — 7.9 kW cooling, 2.68 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FMFT406U (R290 variable-capacity hermetic, LBP, EN12900, 50-60 Hz) Catalog | Compressors | Embraco | R290 compressor — 0.37 kW cooling, 0.23 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH128A6-100 (R22 air-conditioning scroll, 50 Hz, 220 V 3P) Catalog | Compressors | Invotech | R22 compressor — 12.9 kW cooling, 3.73 kW input, COP 3.45 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh THG1365YGS (R134a hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 0.09 kW cooling, 0.10 kW input, COP 0.82 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland ZR108KCE-TFD (R407C scroll, 50 Hz, AC) Catalog | Compressors | Copeland | R407C compressor — 25.8 kW cooling, 7.58 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss LLZ013T2A (R452A scroll, 50 Hz, LT) Catalog | Compressors | Danfoss | R452A compressor — 2.8 kW cooling, 1.85 kW input, COP 1.51 at -35/30 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Embraco FMSA4C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM132A6G-100 (R22 medium-temperature refrigeration scroll, 50 Hz, 220 V 3P) Catalog | Compressors | Invotech | R22 compressor — 21.1 kW cooling, 7.01 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one