Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 2,329–2,352 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Embraco EMT1125U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.17 kW cooling, 0.14 kW input, COP 1.22 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF85E7G-V100 (R404A low-temperature freezing scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR404A compressor — 34.9 kW cooling, 13.80 kW input, COP 2.53 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2428Z-XA1C (R452A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR452A compressor — 0.29 kW cooling, 0.38 kW input, COP 0.76 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ZHW0302P-2E9 (R410A variable-speed scroll) CatalogCompressorsCopelandR410A compressor — 15.0 kW cooling, 3.41 kW input, COP 4.42 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss DCJ091T4A (R410A scroll, 50 Hz) CatalogCompressorsDanfossR410A compressor — 19.7 kW cooling, 6.99 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMU30HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW140J1-100 (R134a heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR134a compressor — 16.0 kW cooling, 4.94 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJK480Z-TZ1C (R407C hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR407C compressor — 1.8 kW cooling, 0.84 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZJ17KHE-PFB (R410A scroll, 60 Hz, AC) CatalogCompressorsCopelandR410A compressor — 4.9 kW cooling, 1.67 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss DSF100-7 (R32 scroll, 60 Hz, HT) CatalogCompressorsDanfossR32 compressor — 29.4 kW cooling, 9.38 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMX20CLC (R600a hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.05 kW cooling, 0.04 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF17A5G-Q100 (R22 low-temperature freezing scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 2.2 kW cooling, 1.88 kW input, COP 1.17 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AKA9451ZXA (R448A hermetic, HBP, ARI, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 2.4 kW cooling, 1.25 kW input, COP 1.89 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZP103KFE-TFD (R410A scroll, 50 Hz, AC) CatalogCompressorsCopelandR410A compressor — 25.1 kW cooling, 7.94 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss DSH090-4 (R454B scroll, 60 Hz, A/C) CatalogCompressorsDanfossR454B compressor — 26.3 kW cooling, 8.18 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY26CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.40 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH128A3-100 (R22 air-conditioning scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR22 compressor — 15.5 kW cooling, 4.64 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AL4510Z-FZ3A (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 2.3 kW cooling, 1.06 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZPD103KCE-TFD (R410A scroll, 50 Hz, AC) CatalogCompressorsCopelandR410A compressor — 25.2 kW cooling, 7.81 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss HCJ105T2 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 26.0 kW cooling, 8.69 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMYE70HEP (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.15 kW cooling, 0.10 kW input, COP 1.57 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM132A1G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR22 compressor — 25.4 kW cooling, 8.42 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh ALX445Z-FZ3A (R404A hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 1.1 kW cooling, 0.65 kW input, COP 1.64 at -25/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ZPDT16MCE-TFE (R410A scroll, 60 Hz, AC) CatalogCompressorsCopelandR410A compressor — 47.6 kW cooling, 15.09 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
‹ Previous1…96979899100…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here