Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 3,001–3,024 of 10,248
Copeland YFH04KAE-PFV (R507 scroll, 60 Hz, LT)
R507 compressor — 0.97 kW cooling, 0.98 kW input, COP 0.99 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH04KAU-TF5 (R290 scroll, 50 Hz, LT)
R290 compressor — 0.71 kW cooling, 0.54 kW input, COP 1.32 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH04KAU-TF5 (R290 scroll, 60 Hz, LT)
R290 compressor — 0.86 kW cooling, 0.65 kW input, COP 1.32 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R404A scroll, 50 Hz, LT)
R404A compressor — 1.1 kW cooling, 1.09 kW input, COP 0.98 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R404A scroll, 60 Hz, LT)
R404A compressor — 1.3 kW cooling, 1.29 kW input, COP 0.99 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R407A scroll, 50 Hz, LT)
R407A compressor — 0.91 kW cooling, 0.97 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R407A scroll, 60 Hz, LT)
R407A compressor — 1.1 kW cooling, 1.16 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R407C scroll, 50 Hz, LT)
R407C compressor — 0.85 kW cooling, 0.94 kW input, COP 0.91 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R407C scroll, 60 Hz, LT)
R407C compressor — 1.0 kW cooling, 1.12 kW input, COP 0.91 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R407F scroll, 50 Hz, LT)
R407F compressor — 0.91 kW cooling, 0.97 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R407F scroll, 60 Hz, LT)
R407F compressor — 1.1 kW cooling, 1.16 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R448A scroll, 50 Hz, LT)
R448A compressor — 0.96 kW cooling, 0.99 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R448A scroll, 60 Hz, LT)
R448A compressor — 1.2 kW cooling, 1.19 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R449A scroll, 50 Hz, LT)
R449A compressor — 0.96 kW cooling, 0.99 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R449A scroll, 60 Hz, LT)
R449A compressor — 1.2 kW cooling, 1.19 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R507 scroll, 50 Hz, LT)
R507 compressor — 1.1 kW cooling, 1.11 kW input, COP 0.99 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAE-TF5 (R507 scroll, 60 Hz, LT)
R507 compressor — 1.3 kW cooling, 1.32 kW input, COP 1.00 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAU-TF5 (R290 scroll, 50 Hz, LT)
R290 compressor — 0.99 kW cooling, 0.76 kW input, COP 1.31 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH05KAU-TF5 (R290 scroll, 60 Hz, LT)
R290 compressor — 1.2 kW cooling, 0.91 kW input, COP 1.31 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH07KAE-TF5 (R404A scroll, 50 Hz, LT)
R404A compressor — 1.5 kW cooling, 1.31 kW input, COP 1.18 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH07KAE-TF5 (R404A scroll, 60 Hz, LT)
R404A compressor — 1.8 kW cooling, 1.55 kW input, COP 1.19 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH07KAE-TF5 (R407A scroll, 50 Hz, LT)
R407A compressor — 1.3 kW cooling, 1.17 kW input, COP 1.13 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH07KAE-TF5 (R407A scroll, 60 Hz, LT)
R407A compressor — 1.6 kW cooling, 1.40 kW input, COP 1.13 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YFH07KAE-TF5 (R407C scroll, 50 Hz, LT)
R407C compressor — 1.2 kW cooling, 1.14 kW input, COP 1.08 at -35/35 °C (evaporating/condensing), inside its published envelope.
Publishing here