Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 3,337–3,360 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Copeland AFE05C4E-IAA (R513A hermetic recip, 60 Hz, EA) CatalogCompressorsCopelandR513A compressor — 0.18 kW cooling, 0.19 kW input, COP 0.97 at -25/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ018-3 (R407C hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 5.0 kW cooling, 1.73 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMYS60HEP (R134a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.10 kW cooling, 0.09 kW input, COP 1.17 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF20E2G-Q100 (R449A low-temperature freezing scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR449A compressor — 2.0 kW cooling, 2.02 kW input, COP 1.01 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh AJK510Z-GZ3B (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 2.3 kW cooling, 1.12 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland AFF07C1E-IAA (R450A hermetic recip, 60 Hz, EF) CatalogCompressorsCopelandR450A compressor — 0.18 kW cooling, 0.13 kW input, COP 1.38 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss NTZ048-4B (R455A hermetic reciprocating, 50 Hz, LT) CatalogCompressorsDanfossR455A compressor — 1.1 kW cooling, 0.91 kW input, COP 1.26 at -30/35 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EMZ55CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.12 kW cooling, 0.07 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH140T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR407C compressor — 16.2 kW cooling, 5.18 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AWS4532ELZ (R22 hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 7.1 kW cooling, 2.40 kW input, COP 2.97 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland AFM06C1U-IAZ (R290 hermetic recip, 50 Hz, LT) CatalogCompressorsCopelandR290 compressor — 0.20 kW cooling, 0.14 kW input, COP 1.40 at -30/45 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss PSH019-7E (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 25.8 kW cooling, 9.02 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FF6HBK (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.75 kW cooling, 0.32 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM210A5G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 40.4 kW cooling, 13.11 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh FH2480Z-XC3A (R449A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 1.3 kW cooling, 1.22 kW input, COP 1.08 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ARE13C4E-IAA (R450A hermetic recip, 60 Hz, HT) CatalogCompressorsCopelandR450A compressor — 0.38 kW cooling, 0.22 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SH120-4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 26.7 kW cooling, 9.46 kW input, COP 2.82 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFI12HAX (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 1.2 kW cooling, 0.60 kW input, COP 2.03 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW205A1-100 (R22 heat-pump water heater scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 22.6 kW cooling, 7.04 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AE2415Y-FZ1B (R134a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 0.17 kW cooling, 0.18 kW input, COP 0.93 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ASE12C4E-IAA (R448A hermetic recip, 60 Hz, MT) CatalogCompressorsCopelandR448A compressor — 0.21 kW cooling, 0.20 kW input, COP 1.07 at -20/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SM110-7 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 31.6 kW cooling, 9.35 kW input, COP 3.38 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFU130HAX (R134a hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.26 kW cooling, 0.21 kW input, COP 1.22 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF20E2G-Q100 (R452A low-temperature freezing scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR452A compressor — 2.1 kW cooling, 2.05 kW input, COP 1.03 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
‹ Previous1…138139140141142…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory