Copeland YS33KAE-TF5 (R455A scroll, 50 Hz, EM)
R455A compressor — 4.6 kW cooling, 2.76 kW input, COP 1.68 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS33KAE-TF5 (R455A scroll, 60 Hz, EM)
R455A compressor — 5.6 kW cooling, 3.31 kW input, COP 1.68 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R404A scroll, 50 Hz, EM)
R404A compressor — 6.7 kW cooling, 3.47 kW input, COP 1.94 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R404A scroll, 60 Hz, EM)
R404A compressor — 8.1 kW cooling, 4.17 kW input, COP 1.94 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R448A scroll, 50 Hz, EM)
R448A compressor — 5.7 kW cooling, 3.50 kW input, COP 1.62 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R448A scroll, 60 Hz, EM)
R448A compressor — 6.8 kW cooling, 4.20 kW input, COP 1.62 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R449A scroll, 50 Hz, EM)
R449A compressor — 5.7 kW cooling, 3.50 kW input, COP 1.62 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R449A scroll, 60 Hz, EM)
R449A compressor — 6.8 kW cooling, 4.20 kW input, COP 1.62 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R454A scroll, 50 Hz, EM)
R454A compressor — 5.9 kW cooling, 3.66 kW input, COP 1.62 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R454A scroll, 60 Hz, EM)
R454A compressor — 7.1 kW cooling, 4.39 kW input, COP 1.62 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R454C scroll, 50 Hz, EM)
R454C compressor — 5.1 kW cooling, 3.00 kW input, COP 1.69 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R454C scroll, 60 Hz, EM)
R454C compressor — 6.1 kW cooling, 3.61 kW input, COP 1.69 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R455A scroll, 50 Hz, EM)
R455A compressor — 5.5 kW cooling, 3.20 kW input, COP 1.72 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R455A scroll, 60 Hz, EM)
R455A compressor — 6.6 kW cooling, 3.84 kW input, COP 1.72 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R507 scroll, 50 Hz, EM)
R507 compressor — 7.1 kW cooling, 3.60 kW input, COP 1.96 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS40KAE-TF5 (R507 scroll, 60 Hz, EM)
R507 compressor — 8.5 kW cooling, 4.32 kW input, COP 1.96 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YSH07KAE-TF5 (R404A scroll, 50 Hz, MT)
R404A compressor — 1.0 kW cooling, 0.61 kW input, COP 1.70 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YSH07KAE-TF5 (R404A scroll, 60 Hz, MT)
R404A compressor — 1.3 kW cooling, 0.74 kW input, COP 1.70 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YSH12KAE-PFV (R407A scroll, 60 Hz, MT)
R407A compressor — 3.0 kW cooling, 1.32 kW input, COP 2.29 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZB06KAE-TF5 (R134A scroll, 50 Hz, MT)
R134a compressor — 1.5 kW cooling, 0.55 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.
Copeland ZB06KAE-TF5 (R134A scroll, 60 Hz, MT)
R134a compressor — 1.7 kW cooling, 0.66 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.
Copeland ZB06KAE-TF5 (R404A scroll, 50 Hz, MT)
R404A compressor — 1.3 kW cooling, 0.60 kW input, COP 2.19 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZB06KAE-TF5 (R404A scroll, 60 Hz, MT)
R404A compressor — 1.6 kW cooling, 0.72 kW input, COP 2.19 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZB06KAE-TF5 (R407A scroll, 50 Hz, MT)
R407A compressor — 1.2 kW cooling, 0.55 kW input, COP 2.14 at -15/35 °C (evaporating/condensing), inside its published envelope.