Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 3,265–3,288 of 10,248
Copeland YS27KAE-TF5 (R454C scroll, 50 Hz, EM)
R454C compressor — 3.4 kW cooling, 2.13 kW input, COP 1.62 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS27KAE-TF5 (R454C scroll, 60 Hz, EM)
R454C compressor — 4.1 kW cooling, 2.55 kW input, COP 1.62 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS27KAE-TF5 (R455A scroll, 50 Hz, EM)
R455A compressor — 3.7 kW cooling, 2.27 kW input, COP 1.65 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS27KAE-TF5 (R455A scroll, 60 Hz, EM)
R455A compressor — 4.5 kW cooling, 2.72 kW input, COP 1.65 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-TF5 (R134A scroll, 50 Hz, HT)
R134a compressor — 8.0 kW cooling, 2.64 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
Copeland YS30KAE-TF5 (R134A scroll, 60 Hz, HT)
R134a compressor — 9.6 kW cooling, 3.17 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
Copeland YS30KAE-PFJ (R404A scroll, 50 Hz, EM)
R404A compressor — 4.8 kW cooling, 2.61 kW input, COP 1.85 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-PFJ (R404A scroll, 60 Hz, EM)
R404A compressor — 5.8 kW cooling, 3.13 kW input, COP 1.85 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-PFJ (R407A scroll, 50 Hz, EM)
R407A compressor — 3.9 kW cooling, 2.55 kW input, COP 1.54 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-PFJ (R407A scroll, 60 Hz, EM)
R407A compressor — 4.7 kW cooling, 3.06 kW input, COP 1.54 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-TF5 (R407C scroll, 50 Hz, HT)
R407C compressor — 11.6 kW cooling, 3.96 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.
Copeland YS30KAE-TF5 (R407C scroll, 60 Hz, HT)
R407C compressor — 14.5 kW cooling, 5.14 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
Copeland YS30KAE-PFJ (R448A scroll, 50 Hz, EM)
R448A compressor — 4.1 kW cooling, 2.61 kW input, COP 1.55 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-PFJ (R448A scroll, 60 Hz, EM)
R448A compressor — 4.9 kW cooling, 3.13 kW input, COP 1.55 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-PFJ (R449A scroll, 50 Hz, EM)
R449A compressor — 4.1 kW cooling, 2.61 kW input, COP 1.55 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-PFJ (R449A scroll, 60 Hz, EM)
R449A compressor — 4.9 kW cooling, 3.13 kW input, COP 1.55 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-PFJ (R507 scroll, 50 Hz, EM)
R507 compressor — 5.0 kW cooling, 2.68 kW input, COP 1.87 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAE-PFJ (R507 scroll, 60 Hz, EM)
R507 compressor — 6.0 kW cooling, 3.22 kW input, COP 1.87 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAU-TF5 (R290 scroll, 50 Hz, MT)
R290 compressor — 4.1 kW cooling, 2.05 kW input, COP 1.98 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS30KAU-TF5 (R290 scroll, 60 Hz, MT)
R290 compressor — 4.9 kW cooling, 2.46 kW input, COP 1.98 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS33KAE-TF5 (R454A scroll, 50 Hz, EM)
R454A compressor — 5.0 kW cooling, 3.16 kW input, COP 1.58 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS33KAE-TF5 (R454A scroll, 60 Hz, EM)
R454A compressor — 6.0 kW cooling, 3.79 kW input, COP 1.58 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS33KAE-TF5 (R454C scroll, 50 Hz, EM)
R454C compressor — 4.3 kW cooling, 2.59 kW input, COP 1.65 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS33KAE-TF5 (R454C scroll, 60 Hz, EM)
R454C compressor — 5.1 kW cooling, 3.11 kW input, COP 1.65 at -25/40 °C (evaporating/condensing), inside its published envelope.