Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 3,409–3,432 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Embraco NEX4180UA (R290 hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.77 kW cooling, 0.55 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM210A8G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 575 V 3P) CatalogCompressorsInvotechR22 compressor — 40.4 kW cooling, 13.11 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJK510Z-HZ3C (R404A hermetic, HBP, Tecumseh Europe, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 3.1 kW cooling, 1.53 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland KCE419HAG-V4H (R134A hermetic recip, 60 Hz, HT) CatalogCompressorsCopelandR134a compressor — 0.54 kW cooling, 0.28 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss HLJ072T4B (R454B scroll, 60 Hz) CatalogCompressorsDanfossR454B compressor — 20.2 kW cooling, 6.24 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NJ2212GK (R404A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 0.81 kW cooling, 0.84 kW input, COP 0.96 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW205A7-100 (R22 heat-pump water heater scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 27.1 kW cooling, 8.46 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AWS4532EXN (R22 hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 7.4 kW cooling, 2.65 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland KCJ430LAL-B3H (R404A hermetic recip, 50 Hz, LT) CatalogCompressorsCopelandR404A compressor — 0.24 kW cooling, 0.37 kW input, COP 0.63 at -35/50 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Danfoss HLM075T4 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 22.1 kW cooling, 6.45 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT2168GK (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 0.33 kW cooling, 0.33 kW input, COP 1.00 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF20E3G-Q100 (R404A low-temperature freezing scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR404A compressor — 2.6 kW cooling, 2.47 kW input, COP 1.06 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh FH2480Z-XG1A (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 1.00 kW cooling, 0.99 kW input, COP 1.00 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland KCM511CAL-B5H (R134A hermetic recip, 50 Hz, MT) CatalogCompressorsCopelandR134a compressor — 3.0 kW cooling, 1.12 kW input, COP 2.63 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss HLP078T2 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 19.2 kW cooling, 5.83 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NTU6234GKV (R404A hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 3.9 kW cooling, 1.75 kW input, COP 2.24 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH140T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P) CatalogCompressorsInvotechR407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AE2415Z-AA1A (R404A hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 0.28 kW cooling, 0.26 kW input, COP 1.06 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland KCN396LAG-BXH (R134A hermetic recip, 50 Hz, LT) CatalogCompressorsCopelandR134a compressor — 0.13 kW cooling, 0.17 kW input, COP 0.79 at -30/50 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Danfoss HRH031U1 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 9.1 kW cooling, 3.04 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NTX6225UV (R290 hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 3.1 kW cooling, 1.33 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM210E1G-100 (R404A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 32.6 kW cooling, 12.27 kW input, COP 2.66 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AG2516P-TZ1A (R449A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 2.1 kW cooling, 1.85 kW input, COP 1.12 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland RFT22C1E-CAA (R404A hermetic recip, 60 Hz, LT) CatalogCompressorsCopelandR404A compressor — 0.54 kW cooling, 0.49 kW input, COP 1.10 at -30/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…141142143144145…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one