Copeland ZBD114K5E-TFD (R134A scroll, 50 Hz, HT)
R134a compressor — 27.7 kW cooling, 9.72 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD114K5E-TFD (R134A scroll, 60 Hz, HT)
R134a compressor — 34.0 kW cooling, 11.36 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD114K5E-TFD (R404A scroll, 50 Hz, MT)
R404A compressor — 27.3 kW cooling, 9.08 kW input, COP 3.01 at -15/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD114K5E-TFD (R404A scroll, 60 Hz, MT)
R404A compressor — 33.1 kW cooling, 11.17 kW input, COP 2.96 at -15/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD114K5E-TFD (R407C scroll, 50 Hz, HT)
R407C compressor — 40.5 kW cooling, 13.65 kW input, COP 2.97 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD114K5E-TFD (R407C scroll, 60 Hz, HT)
R407C compressor — 49.0 kW cooling, 16.41 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD114K5E-TFD (R448A scroll, 60 Hz, MT)
R448A compressor — 29.7 kW cooling, 9.78 kW input, COP 3.04 at -15/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD114K5E-TFD (R449A scroll, 60 Hz, MT)
R449A compressor — 29.7 kW cooling, 9.78 kW input, COP 3.04 at -15/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD114K5E-TFD (R513A scroll, 50 Hz, HT)
R513A compressor — 27.8 kW cooling, 10.18 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD114K5E-TFD (R513A scroll, 60 Hz, HT)
R513A compressor — 33.3 kW cooling, 12.22 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD21KCE-PFV (R134A scroll, 60 Hz, HT)
R134a compressor — 6.5 kW cooling, 2.28 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD21KCE-TF5 (R404A scroll, 50 Hz, MT)
R404A compressor — 4.9 kW cooling, 2.05 kW input, COP 2.38 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TF5 (R404A scroll, 60 Hz, MT)
R404A compressor — 5.9 kW cooling, 2.46 kW input, COP 2.38 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TF5 (R407A scroll, 50 Hz, MT)
R407A compressor — 4.4 kW cooling, 1.85 kW input, COP 2.36 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TF5 (R407A scroll, 60 Hz, MT)
R407A compressor — 5.2 kW cooling, 2.23 kW input, COP 2.36 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TF5 (R407C scroll, 50 Hz, MT)
R407C compressor — 7.8 kW cooling, 2.76 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD21KCE-TF5 (R407C scroll, 60 Hz, MT)
R407C compressor — 9.4 kW cooling, 3.31 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD21KCE-TF5 (R407F scroll, 50 Hz, MT)
R407F compressor — 4.4 kW cooling, 1.85 kW input, COP 2.36 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TF5 (R407F scroll, 60 Hz, MT)
R407F compressor — 5.2 kW cooling, 2.23 kW input, COP 2.36 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TFD (R448A scroll, 50 Hz, MT)
R448A compressor — 4.3 kW cooling, 1.66 kW input, COP 2.58 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TF5 (R448A scroll, 60 Hz, MT)
R448A compressor — 5.4 kW cooling, 2.28 kW input, COP 2.37 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TF5 (R449A scroll, 50 Hz, MT)
R449A compressor — 4.5 kW cooling, 1.90 kW input, COP 2.37 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TF5 (R449A scroll, 60 Hz, MT)
R449A compressor — 5.4 kW cooling, 2.28 kW input, COP 2.37 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-TF5 (R507 scroll, 50 Hz, MT)
R507 compressor — 5.1 kW cooling, 2.09 kW input, COP 2.42 at -15/35 °C (evaporating/condensing), inside its published envelope.