Copeland ZBD21KCE-TF5 (R507 scroll, 60 Hz, MT)
R507 compressor — 6.1 kW cooling, 2.51 kW input, COP 2.42 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KCE-PFJ (R513A scroll, 50 Hz, HT)
R513A compressor — 5.3 kW cooling, 2.03 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD21KCE-PFV (R513A scroll, 60 Hz, HT)
R513A compressor — 6.3 kW cooling, 2.43 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD21KQE-TFD (R134A scroll, 50 Hz, MT)
R134a compressor — 2.7 kW cooling, 1.29 kW input, COP 2.06 at -15/40 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KQE-TFD (R134A scroll, 60 Hz, MT)
R134a compressor — 3.2 kW cooling, 1.54 kW input, COP 2.06 at -15/40 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KQE-TFD (R404A scroll, 50 Hz, MT)
R404A compressor — 4.8 kW cooling, 1.83 kW input, COP 2.62 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD21KQE-TFD (R404A scroll, 60 Hz, MT)
R404A compressor — 5.8 kW cooling, 2.25 kW input, COP 2.58 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFV (R134A scroll, 60 Hz, HT)
R134a compressor — 8.6 kW cooling, 2.97 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD29KCE-PFJ (R404A scroll, 50 Hz, MT)
R404A compressor — 6.5 kW cooling, 2.71 kW input, COP 2.42 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFV (R404A scroll, 60 Hz, MT)
R404A compressor — 7.8 kW cooling, 3.25 kW input, COP 2.42 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFJ (R407A scroll, 50 Hz, MT)
R407A compressor — 5.8 kW cooling, 2.47 kW input, COP 2.37 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFV (R407A scroll, 60 Hz, MT)
R407A compressor — 7.0 kW cooling, 2.96 kW input, COP 2.37 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFV (R407C scroll, 60 Hz, HT)
R407C compressor — 12.6 kW cooling, 4.39 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD29KCE-PFJ (R407F scroll, 50 Hz, MT)
R407F compressor — 5.8 kW cooling, 2.47 kW input, COP 2.37 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFV (R407F scroll, 60 Hz, MT)
R407F compressor — 7.0 kW cooling, 2.96 kW input, COP 2.37 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-TFD (R448A scroll, 50 Hz, MT)
R448A compressor — 6.1 kW cooling, 2.23 kW input, COP 2.75 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFV (R448A scroll, 60 Hz, MT)
R448A compressor — 7.2 kW cooling, 3.02 kW input, COP 2.38 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFJ (R449A scroll, 50 Hz, MT)
R449A compressor — 6.0 kW cooling, 2.52 kW input, COP 2.38 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFV (R449A scroll, 60 Hz, MT)
R449A compressor — 7.2 kW cooling, 3.02 kW input, COP 2.38 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFJ (R507 scroll, 50 Hz, MT)
R507 compressor — 6.8 kW cooling, 2.77 kW input, COP 2.45 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFV (R507 scroll, 60 Hz, MT)
R507 compressor — 8.1 kW cooling, 3.32 kW input, COP 2.45 at -15/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZBD29KCE-PFV (R513A scroll, 60 Hz, HT)
R513A compressor — 8.5 kW cooling, 3.11 kW input, COP 2.72 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD29KQ-TFD (R22 scroll, 50 Hz, HT)
R22 compressor — 10.9 kW cooling, 3.54 kW input, COP 3.09 at the AHRI 7.2/54.4 °C rating point.
Copeland ZBD29KQ-TFD (R22 scroll, 60 Hz, HT)
R22 compressor — 13.1 kW cooling, 4.25 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.