Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 3,817–3,840 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Copeland 2DB3F25KE-TFC (R448A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R448A compressor — 6.0 kW cooling, 3.48 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ015T1C (R454A scroll, 60 Hz) Catalog | Compressors | Danfoss | R454A compressor — 6.7 kW cooling, 2.62 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMI32CLP (R600a hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.07 kW cooling, 0.07 kW input, COP 1.00 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF25E1G-Q100 (R448A low-temperature freezing scroll, 50 Hz, 380 V 3P) Catalog | Compressors | Invotech | R448A compressor — 2.6 kW cooling, 2.59 kW input, COP 1.02 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AGB4553ZTZ (R22 hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R22 compressor — 14.0 kW cooling, 6.03 kW input, COP 2.32 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 2DC3R53KE-TFD (R407A Discus recip, 60 Hz, AC) Catalog | Compressors | Copeland | R407A compressor — 18.3 kW cooling, 5.43 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss MT028-4 (R22 hermetic reciprocating, 50 Hz, MT) Catalog | Compressors | Danfoss | R22 compressor — 7.4 kW cooling, 2.55 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMIE40HER (R134a hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.08 kW cooling, 0.07 kW input, COP 1.15 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH150T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P) Catalog | Compressors | Invotech | R407C compressor — 17.4 kW cooling, 5.55 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AJ2432Z-XA3B (R448A hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R448A compressor — 0.45 kW cooling, 0.54 kW input, COP 0.84 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 2DD3R63KE-TFC (R449A Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R449A compressor — 10.1 kW cooling, 3.71 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ018-3 (R452A hermetic reciprocating, 60 Hz, MT) Catalog | Compressors | Danfoss | R452A compressor — 4.4 kW cooling, 2.04 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMIS70HHR (R134a hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.68 kW cooling, 0.31 kW input, COP 2.17 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM34E2G-100 (R449A medium-temperature refrigeration scroll, 50 Hz, 220 V 1P) Catalog | Compressors | Invotech | R449A compressor — 5.7 kW cooling, 2.16 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh AJK510Z-TZ1C (R452A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R452A compressor — 2.7 kW cooling, 1.50 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 2DF3F16KE-TFC (R448A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R448A compressor — 3.9 kW cooling, 2.38 kW input, COP 1.66 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss NTZ048-5B (R454C hermetic reciprocating, 50 Hz, LT) Catalog | Compressors | Danfoss | R454C compressor — 1.1 kW cooling, 0.85 kW input, COP 1.27 at -30/35 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Embraco EMR55CLP (R600a hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YW245T8-100 (R407C heat-pump water heater scroll, 60 Hz, 575 V 3P) Catalog | Compressors | Invotech | R407C compressor — 31.1 kW cooling, 10.14 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AWS4538ZXN (R404A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R404A compressor — 10.1 kW cooling, 3.62 kW input, COP 2.80 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 2DL3F20KE-TFC (R448A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R448A compressor — 4.7 kW cooling, 2.78 kW input, COP 1.69 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss PSH023-3 (R410A scroll, 60 Hz) Catalog | Compressors | Danfoss | R410A compressor — 30.7 kW cooling, 10.11 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMT2125U (R290 hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R290 compressor — 0.14 kW cooling, 0.12 kW input, COP 1.13 at -40/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF25E1G-Q100 (R449A low-temperature freezing scroll, 50 Hz, 380 V 3P) Catalog | Compressors | Invotech | R449A compressor — 2.6 kW cooling, 2.59 kW input, COP 1.02 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here