Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 4,057–4,080 of 10,248
Copeland ZF03KAE-TF5 (R449A scroll, 50 Hz, LL)
R449A compressor — 0.56 kW cooling, 0.60 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF03KAE-TF5 (R449A scroll, 60 Hz, LL)
R449A compressor — 0.68 kW cooling, 0.72 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R404A scroll, 50 Hz, LL)
R404A compressor — 0.79 kW cooling, 0.80 kW input, COP 0.98 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R404A scroll, 60 Hz, LL)
R404A compressor — 0.94 kW cooling, 0.95 kW input, COP 0.99 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R407A scroll, 50 Hz, LL)
R407A compressor — 0.67 kW cooling, 0.71 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R407A scroll, 60 Hz, LL)
R407A compressor — 0.81 kW cooling, 0.86 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R407C scroll, 50 Hz, LL)
R407C compressor — 0.63 kW cooling, 0.69 kW input, COP 0.91 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R407C scroll, 60 Hz, LL)
R407C compressor — 0.75 kW cooling, 0.83 kW input, COP 0.91 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R407F scroll, 50 Hz, LL)
R407F compressor — 0.67 kW cooling, 0.71 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R407F scroll, 60 Hz, LL)
R407F compressor — 0.81 kW cooling, 0.86 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R448A scroll, 50 Hz, LL)
R448A compressor — 0.71 kW cooling, 0.73 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R448A scroll, 60 Hz, LL)
R448A compressor — 0.85 kW cooling, 0.88 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R449A scroll, 50 Hz, LL)
R449A compressor — 0.71 kW cooling, 0.73 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF04KAE-TF5 (R449A scroll, 60 Hz, LL)
R449A compressor — 0.85 kW cooling, 0.88 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R404A scroll, 50 Hz, LL)
R404A compressor — 0.97 kW cooling, 0.89 kW input, COP 1.08 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R404A scroll, 60 Hz, LL)
R404A compressor — 1.2 kW cooling, 1.12 kW input, COP 1.03 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R407A scroll, 50 Hz, LL)
R407A compressor — 0.79 kW cooling, 0.87 kW input, COP 0.90 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R407A scroll, 60 Hz, LL)
R407A compressor — 0.95 kW cooling, 1.05 kW input, COP 0.90 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R407C scroll, 50 Hz, LL)
R407C compressor — 0.74 kW cooling, 0.83 kW input, COP 0.89 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R407C scroll, 60 Hz, LL)
R407C compressor — 0.88 kW cooling, 1.00 kW input, COP 0.89 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R407F scroll, 50 Hz, LL)
R407F compressor — 0.79 kW cooling, 0.87 kW input, COP 0.90 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R407F scroll, 60 Hz, LL)
R407F compressor — 0.95 kW cooling, 1.05 kW input, COP 0.90 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R448A scroll, 50 Hz, LL)
R448A compressor — 0.85 kW cooling, 0.89 kW input, COP 0.95 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF05KAE-TF5 (R448A scroll, 60 Hz, LL)
R448A compressor — 1.0 kW cooling, 1.07 kW input, COP 0.95 at -35/35 °C (evaporating/condensing), inside its published envelope.