Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 4,105–4,128 of 10,248
Copeland ZF06KAE-TF5 (R407F scroll, 60 Hz, LL)
R407F compressor — 1.4 kW cooling, 1.25 kW input, COP 1.08 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KAE-TF5 (R448A scroll, 50 Hz, LL)
R448A compressor — 1.2 kW cooling, 1.05 kW input, COP 1.12 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KAE-TF5 (R448A scroll, 60 Hz, LL)
R448A compressor — 1.4 kW cooling, 1.25 kW input, COP 1.12 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KAE-TF5 (R449A scroll, 50 Hz, LL)
R449A compressor — 1.2 kW cooling, 1.05 kW input, COP 1.12 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KAE-TF5 (R449A scroll, 60 Hz, LL)
R449A compressor — 1.4 kW cooling, 1.25 kW input, COP 1.12 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KAE-TF5 (R507 scroll, 50 Hz, LL)
R507 compressor — 1.3 kW cooling, 1.15 kW input, COP 1.15 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KAE-TF5 (R507 scroll, 60 Hz, LL)
R507 compressor — 1.6 kW cooling, 1.38 kW input, COP 1.15 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TFD (R22 scroll, 50 Hz, LL)
R22 compressor — 1.5 kW cooling, 1.24 kW input, COP 1.17 at -35/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TFC (R22 scroll, 60 Hz, LL)
R22 compressor — 1.7 kW cooling, 1.35 kW input, COP 1.23 at -35/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TFD (R404A scroll, 50 Hz, LL)
R404A compressor — 1.5 kW cooling, 1.24 kW input, COP 1.23 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TFC (R404A scroll, 60 Hz, LL)
R404A compressor — 1.8 kW cooling, 1.42 kW input, COP 1.26 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TF5 (R407A scroll, 50 Hz, LL)
R407A compressor — 1.3 kW cooling, 1.21 kW input, COP 1.06 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TF5 (R407A scroll, 60 Hz, LL)
R407A compressor — 1.5 kW cooling, 1.31 kW input, COP 1.14 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TF5 (R407C scroll, 60 Hz, LL)
R407C compressor — 1.4 kW cooling, 1.25 kW input, COP 1.10 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TF5 (R407F scroll, 50 Hz, LL)
R407F compressor — 1.3 kW cooling, 1.21 kW input, COP 1.06 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TF5 (R407F scroll, 60 Hz, LL)
R407F compressor — 1.5 kW cooling, 1.31 kW input, COP 1.14 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TF5 (R448A scroll, 50 Hz, LL)
R448A compressor — 1.3 kW cooling, 0.44 kW input, COP 2.95 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TF5 (R448A scroll, 60 Hz, LL)
R448A compressor — 1.5 kW cooling, 1.16 kW input, COP 1.32 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TF5 (R449A scroll, 50 Hz, LL)
R449A compressor — 1.3 kW cooling, 0.44 kW input, COP 2.95 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TF5 (R449A scroll, 60 Hz, LL)
R449A compressor — 1.5 kW cooling, 1.17 kW input, COP 1.29 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TFD (R507 scroll, 50 Hz, LL)
R507 compressor — 1.5 kW cooling, 1.34 kW input, COP 1.14 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF06KQE-TFC (R507 scroll, 60 Hz, LL)
R507 compressor — 1.8 kW cooling, 1.42 kW input, COP 1.26 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF07KAE-TF5 (R404A scroll, 50 Hz, LL)
R404A compressor — 1.5 kW cooling, 1.31 kW input, COP 1.18 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF07KAE-TF5 (R404A scroll, 60 Hz, LL)
R404A compressor — 1.8 kW cooling, 1.55 kW input, COP 1.19 at -35/35 °C (evaporating/condensing), inside its published envelope.