Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 4,129–4,152 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Embraco EMY3117U (R290 hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.20 kW cooling, 0.12 kW input, COP 1.67 at -25/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM34U1G-100 (R455A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR455A compressor — 5.6 kW cooling, 2.01 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AJK513Z-GZ3C (R407C hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR407C compressor — 2.9 kW cooling, 1.26 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJ3R28ME-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 47.5 kW cooling, 17.00 kW input, COP 2.80 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLJ072T9 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 20.7 kW cooling, 6.78 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMYS80HSP (R134a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.16 kW cooling, 0.08 kW input, COP 1.90 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW300C1-100 (R410A heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR410A compressor — 39.7 kW cooling, 12.96 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh FH2511P-XC3A (R455A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR455A compressor — 1.6 kW cooling, 1.49 kW input, COP 1.08 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DJNF76KE-TSK (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 18.2 kW cooling, 10.34 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLM081T1 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 23.1 kW cooling, 6.98 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMZ70CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.15 kW cooling, 0.09 kW input, COP 1.68 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF29A1G-Q100 (R22 low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 3.2 kW cooling, 2.50 kW input, COP 1.30 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh AE2420Z-AA1B (R404A hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 0.33 kW cooling, 0.33 kW input, COP 0.99 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DJNR19ML-TSK (R513A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR513A compressor — 31.1 kW cooling, 12.03 kW input, COP 2.59 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLP081T2 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 23.7 kW cooling, 7.22 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FF7,5HBK (R134a hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.54 kW cooling, 0.30 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH175C8-100 (R410A air-conditioning scroll, 60 Hz, 575 V 3P) CatalogCompressorsInvotechR410A compressor — 20.9 kW cooling, 6.71 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2516Z-TZ1D (R449A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 2.5 kW cooling, 2.22 kW input, COP 1.14 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DJXF76KE-TSK (R407C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407C compressor — 15.7 kW cooling, 9.68 kW input, COP 1.62 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH032U1 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 9.4 kW cooling, 3.10 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFI12HBK (R134a hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 1.0 kW cooling, 0.50 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM350E1G-100 (R404A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 50.8 kW cooling, 20.60 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AGB4553ZTZ (R452A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR452A compressor — 13.0 kW cooling, 6.19 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJXR19ML-TSK (R513A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR513A compressor — 31.1 kW cooling, 12.03 kW input, COP 2.59 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…171172173174175…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one