Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 4,153–4,176 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss HRM038U2 (R22 scroll, 50 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 9.2 kW cooling, 2.94 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFU130UAX (R290 hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.29 kW cooling, 0.20 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW320A1-100 (R22 heat-pump water heater scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 35.3 kW cooling, 10.70 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AJ2440P-FZ3A (R455A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR455A compressor — 0.44 kW cooling, 0.45 kW input, COP 0.96 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DK3R22ME-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 40.1 kW cooling, 14.45 kW input, COP 2.77 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRP040T5 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 9.4 kW cooling, 3.14 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFUS80HAK (R134a hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.17 kW cooling, 0.12 kW input, COP 1.36 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF29A1G-Q100 (R22 low-temperature freezing scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR22 compressor — 3.9 kW cooling, 3.01 kW input, COP 1.30 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AJK513Z-GZ3C (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 3.0 kW cooling, 1.34 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DKNF63KE-TSK (R448A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR448A compressor — 15.6 kW cooling, 9.01 kW input, COP 1.73 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ013T2C (R455A scroll, 50 Hz) CatalogCompressorsDanfossR455A compressor — 2.9 kW cooling, 1.82 kW input, COP 1.58 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco FMFT411U (R290 variable-capacity hermetic, LBP, EN12900) CatalogCompressorsEmbracoR290 compressor — 0.64 kW cooling, 0.39 kW input, COP 1.64 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH175T1-100 (R407C air-conditioning scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR407C compressor — 16.9 kW cooling, 5.15 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh FH2511P-XG1A (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 1.4 kW cooling, 1.43 kW input, COP 0.97 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DKNR16ML-TSK (R513A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR513A compressor — 25.2 kW cooling, 9.71 kW input, COP 2.60 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLM045T4 (R22 scroll, 60 Hz, MT) CatalogCompressorsDanfossR22 compressor — 20.3 kW cooling, 6.17 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK2125GK (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 0.17 kW cooling, 0.20 kW input, COP 0.88 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM350E1G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR404A compressor — 61.3 kW cooling, 24.87 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AE2420Z-AA1B (R448A hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 0.45 kW cooling, 0.33 kW input, COP 1.35 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DKNS16ME-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 33.7 kW cooling, 12.52 kW input, COP 2.69 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T1C (R513A scroll, 60 Hz, MT) CatalogCompressorsDanfossR513A compressor — 4.3 kW cooling, 1.70 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEU2155U (R290 hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.39 kW cooling, 0.37 kW input, COP 1.07 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW320A1-100 (R22 heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR22 compressor — 42.3 kW cooling, 12.85 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2516Z-TZ1D (R452A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 1.4 kW cooling, 1.63 kW input, COP 0.88 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
‹ Previous1…172173174175176…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one