Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 4,201–4,224 of 10,248
Copeland ZF09KQE-TF5 (R407C scroll, 60 Hz, LL)
R407C compressor — 1.9 kW cooling, 1.65 kW input, COP 1.17 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF09KQE-TF5 (R407F scroll, 50 Hz, LL)
R407F compressor — 1.7 kW cooling, 1.57 kW input, COP 1.07 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF09KQE-TF5 (R407F scroll, 60 Hz, LL)
R407F compressor — 2.0 kW cooling, 1.73 kW input, COP 1.19 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF09KQE-TF5 (R448A scroll, 50 Hz, LL)
R448A compressor — 1.8 kW cooling, 1.49 kW input, COP 1.18 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF09KQE-TF5 (R448A scroll, 60 Hz, LL)
R448A compressor — 2.2 kW cooling, 1.72 kW input, COP 1.27 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF09KQE-TF5 (R449A scroll, 50 Hz, LL)
R449A compressor — 1.8 kW cooling, 1.49 kW input, COP 1.18 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF09KQE-TF5 (R449A scroll, 60 Hz, LL)
R449A compressor — 2.2 kW cooling, 1.72 kW input, COP 1.27 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF09KQE-TFC (R507 scroll, 50 Hz, LL)
R507 compressor — 2.1 kW cooling, 1.62 kW input, COP 1.27 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF09KQE-TFC (R507 scroll, 60 Hz, LL)
R507 compressor — 2.5 kW cooling, 1.79 kW input, COP 1.41 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R134A scroll, 50 Hz, LL)
R134a compressor — 1.5 kW cooling, 1.21 kW input, COP 1.24 at -30/40 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R134A scroll, 60 Hz, LL)
R134a compressor — 1.8 kW cooling, 1.45 kW input, COP 1.24 at -30/40 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R404A scroll, 50 Hz, LL)
R404A compressor — 3.5 kW cooling, 1.66 kW input, COP 2.09 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R404A scroll, 60 Hz, LL)
R404A compressor — 4.2 kW cooling, 1.99 kW input, COP 2.09 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R407A scroll, 50 Hz, LL)
R407A compressor — 2.9 kW cooling, 1.50 kW input, COP 1.93 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R407A scroll, 60 Hz, LL)
R407A compressor — 3.5 kW cooling, 1.80 kW input, COP 1.93 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R407C scroll, 60 Hz, LL)
R407C compressor — 3.2 kW cooling, 1.71 kW input, COP 1.87 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R407F scroll, 50 Hz, LL)
R407F compressor — 2.9 kW cooling, 1.50 kW input, COP 1.93 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R407F scroll, 60 Hz, LL)
R407F compressor — 3.5 kW cooling, 1.80 kW input, COP 1.93 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R448A scroll, 50 Hz, LL)
R448A compressor — 3.0 kW cooling, 1.55 kW input, COP 1.94 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R448A scroll, 60 Hz, LL)
R448A compressor — 3.6 kW cooling, 1.86 kW input, COP 1.94 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R449A scroll, 50 Hz, LL)
R449A compressor — 3.0 kW cooling, 1.55 kW input, COP 1.94 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R449A scroll, 60 Hz, LL)
R449A compressor — 3.6 kW cooling, 1.86 kW input, COP 1.94 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R507 scroll, 50 Hz, LL)
R507 compressor — 3.6 kW cooling, 1.71 kW input, COP 2.13 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland ZF11K4E-TF5 (R507 scroll, 60 Hz, LL)
R507 compressor — 4.4 kW cooling, 2.06 kW input, COP 2.13 at -30/25 °C (evaporating/condensing), inside its published envelope.
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one