Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 4,465–4,488 of 10,248
Copeland ZFD41K5E-TFC (R507 scroll, 50 Hz, LL)
R507 compressor — 9.4 kW cooling, 5.99 kW input, COP 1.56 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFC (R507 scroll, 60 Hz, LL)
R507 compressor — 11.3 kW cooling, 7.19 kW input, COP 1.56 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R404A scroll, 50 Hz, LT)
R404A compressor — 0.60 kW cooling, 0.62 kW input, COP 0.96 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R404A scroll, 60 Hz, LT)
R404A compressor — 0.72 kW cooling, 0.74 kW input, COP 0.96 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R407A scroll, 50 Hz, LT)
R407A compressor — 0.53 kW cooling, 0.58 kW input, COP 0.92 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R407A scroll, 60 Hz, LT)
R407A compressor — 0.64 kW cooling, 0.70 kW input, COP 0.92 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R407C scroll, 50 Hz, LT)
R407C compressor — 0.50 kW cooling, 0.57 kW input, COP 0.89 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R407C scroll, 60 Hz, LT)
R407C compressor — 0.61 kW cooling, 0.68 kW input, COP 0.89 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R407F scroll, 50 Hz, LT)
R407F compressor — 0.53 kW cooling, 0.58 kW input, COP 0.92 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R407F scroll, 60 Hz, LT)
R407F compressor — 0.64 kW cooling, 0.70 kW input, COP 0.92 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R448A scroll, 50 Hz, LT)
R448A compressor — 0.56 kW cooling, 0.60 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R448A scroll, 60 Hz, LT)
R448A compressor — 0.68 kW cooling, 0.72 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R449A scroll, 50 Hz, LT)
R449A compressor — 0.56 kW cooling, 0.60 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R449A scroll, 60 Hz, LT)
R449A compressor — 0.68 kW cooling, 0.72 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R507 scroll, 50 Hz, LT)
R507 compressor — 0.61 kW cooling, 0.64 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH03KAE-TF5 (R507 scroll, 60 Hz, LT)
R507 compressor — 0.74 kW cooling, 0.76 kW input, COP 0.97 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH04KAE-TF5 (R404A scroll, 50 Hz, LT)
R404A compressor — 0.79 kW cooling, 0.80 kW input, COP 0.98 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH04KAE-TF5 (R404A scroll, 60 Hz, LT)
R404A compressor — 0.94 kW cooling, 0.95 kW input, COP 0.99 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH04KAE-TF5 (R407A scroll, 50 Hz, LT)
R407A compressor — 0.67 kW cooling, 0.71 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH04KAE-TF5 (R407A scroll, 60 Hz, LT)
R407A compressor — 0.81 kW cooling, 0.86 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH04KAE-TF5 (R407C scroll, 50 Hz, LT)
R407C compressor — 0.63 kW cooling, 0.69 kW input, COP 0.91 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH04KAE-TF5 (R407C scroll, 60 Hz, LT)
R407C compressor — 0.75 kW cooling, 0.83 kW input, COP 0.91 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH04KAE-TF5 (R407F scroll, 50 Hz, LT)
R407F compressor — 0.67 kW cooling, 0.71 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFH04KAE-TF5 (R407F scroll, 60 Hz, LT)
R407F compressor — 0.81 kW cooling, 0.86 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.