Copeland ZF54K5E-TFD (R407C scroll, 60 Hz, LL)
R407C compressor — 11.4 kW cooling, 8.41 kW input, COP 1.36 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54K5E-TFD (R407F scroll, 50 Hz, LL)
R407F compressor — 10.1 kW cooling, 7.46 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54K5E-TFD (R407F scroll, 60 Hz, LL)
R407F compressor — 12.1 kW cooling, 8.96 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54K5E-TFD (R448A scroll, 60 Hz, LL)
R448A compressor — 12.6 kW cooling, 8.81 kW input, COP 1.43 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54K5E-TFD (R449A scroll, 60 Hz, LL)
R449A compressor — 12.6 kW cooling, 8.81 kW input, COP 1.43 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54KQE-TFD (R22 scroll, 60 Hz, LL)
R22 compressor — 11.4 kW cooling, 7.62 kW input, COP 1.49 at -35/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54KQE-TFD (R404A scroll, 50 Hz, LL)
R404A compressor — 12.2 kW cooling, 8.23 kW input, COP 1.48 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54KQE-TFD (R404A scroll, 60 Hz, LL)
R404A compressor — 14.7 kW cooling, 9.88 kW input, COP 1.48 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54KQE-TFD (R407A scroll, 50 Hz, LL)
R407A compressor — 10.1 kW cooling, 7.46 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54KQE-TFD (R407A scroll, 60 Hz, LL)
R407A compressor — 12.1 kW cooling, 8.96 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54KQE-TFD (R407C scroll, 60 Hz, LL)
R407C compressor — 10.8 kW cooling, 8.38 kW input, COP 1.29 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF54KQE-TFD (R507 scroll, 50 Hz, LL)
R507 compressor — 15.1 kW cooling, 10.08 kW input, COP 1.50 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R404A scroll, 50 Hz, LL)
R404A compressor — 9.1 kW cooling, 5.85 kW input, COP 1.55 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R404A scroll, 60 Hz, LL)
R404A compressor — 10.9 kW cooling, 7.05 kW input, COP 1.55 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R407A scroll, 50 Hz, LL)
R407A compressor — 7.7 kW cooling, 5.59 kW input, COP 1.38 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R407A scroll, 60 Hz, LL)
R407A compressor — 9.3 kW cooling, 6.74 kW input, COP 1.38 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R407C scroll, 50 Hz, LL)
R407C compressor — 7.1 kW cooling, 5.43 kW input, COP 1.30 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R407C scroll, 60 Hz, LL)
R407C compressor — 8.5 kW cooling, 6.51 kW input, COP 1.30 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R407F scroll, 50 Hz, LL)
R407F compressor — 7.7 kW cooling, 5.59 kW input, COP 1.38 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R407F scroll, 60 Hz, LL)
R407F compressor — 9.3 kW cooling, 6.74 kW input, COP 1.38 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R448A scroll, 50 Hz, LL)
R448A compressor — 7.8 kW cooling, 4.91 kW input, COP 1.58 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R448A scroll, 60 Hz, LL)
R448A compressor — 9.5 kW cooling, 5.94 kW input, COP 1.60 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R449A scroll, 50 Hz, LL)
R449A compressor — 7.8 kW cooling, 4.91 kW input, COP 1.58 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZFD41K5E-TFD (R449A scroll, 60 Hz, LL)
R449A compressor — 9.5 kW cooling, 5.94 kW input, COP 1.60 at -35/35 °C (evaporating/condensing), inside its published envelope.