| Sigma SRK-W-4-E24-1R panel radiator (wall mount, E24 element, 1 row), per foot Catalog | Radiators and emitters | Sigma | Hydronic emitter rated per foot of active length: 0.249 kW at an excess of 52.8 K, exponent 1.3. | NA | Open in the builder |
| Tecumseh AL4461Y-FZ1A (R134a hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 1.5 kW cooling, 0.68 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| DRI HRW-4800-MS 270A (N) total energy recovery wheel Catalog AHRI 1060 (air-to-air energy recovery component) | Recovery cores | DRI | Sensible-and-latent recovery core, 8.713 m² face a stream, 17.43 / 17.43 m³/s. | NA | Open in the builder |
| Ziehl-Abegg MAXventowlet DN10V-ZIF.GQ.11.G3 art. 187315 (large axial Ø1000, EC 3~ 400/460 V, with guard grille) Catalog | Fans | Ziehl-Abegg | Fan rated 7.92 m³/s at 4.47 kW. | EU | Open in the builder |
| Grundfos TP 100-320/4 in-line pump, 4-pole Catalog | Pumps | Grundfos | Pump rated 23.39 kg/s at 11.36 kW. | EU | Open in the builder |
| Powrmatic CPx 45 gas cabinet heater (45 kW output) Catalog | Heaters | Powrmatic | Air heater, 45.0 kW at 0.86 m³/s. | EU | Open in the builder |
| Sigma SRK-W-4-E24-2R panel radiator (wall mount, E24 element, 2 rows), per foot Catalog | Radiators and emitters | Sigma | Hydronic emitter rated per foot of active length: 0.340 kW at an excess of 52.8 K, exponent 1.3. | NA | Open in the builder |
| BITZER 4NES-20Y (R449A semi-hermetic recip, EN 12900) Catalog | Compressors | Bitzer | R449A compressor — 48.3 kW cooling, 15.25 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point. | | Open in the builder |
| DRI HRW-500-MS 200 (N) total energy recovery wheel Catalog AHRI 1060 (air-to-air energy recovery component) | Recovery cores | DRI | Sensible-and-latent recovery core, 0.076 m² face a stream, 0.15 / 0.15 m³/s. | NA | Open in the builder |
| Acme 2140 belt-drive in-line airfoil centrifugal exhauster (40.25 in. wheel, 1320 rpm, 50 HP) Catalog | Fans | Acme Engineering & Manufacturing | Fan rated 11.15 m³/s at 36.71 kW. | NA | Open in the builder |
| KSB Etaline L 080-080-115 in-line pump, 2900 rpm Catalog | Pumps | KSB | Pump rated 10.54 kg/s at 1.85 kW. | EU | Open in the builder |
| King KFUH2030-3-2S3-ECM electric unit heater (30 kW, 208 V 3-phase) Catalog | Heaters | King Electric | Air heater, 30.0 kW at 0.98 m³/s. | NA | Open in the builder |
| Sigma SRK-W-5-CV2-2H-4CC panel radiator (wall mount, CV2-2H-4CC coil), per foot Catalog | Radiators and emitters | Sigma | Hydronic emitter rated per foot of active length: 0.296 kW at an excess of 52.8 K, exponent 1.3. | NA | Open in the builder |
| Copeland 2YF3F13KL-TFC (R454A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R454A compressor — 4.6 kW cooling, 2.78 kW input, COP 1.65 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| DRI HRW-500-MS 270A (N) total energy recovery wheel Catalog AHRI 1060 (air-to-air energy recovery component) | Recovery cores | DRI | Sensible-and-latent recovery core, 0.076 m² face a stream, 0.15 / 0.15 m³/s. | NA | Open in the builder |
| CaptiveAire USBI13DD-RM direct-drive general and restaurant duty utility set (Catalog #110C, November 2024; 2252 rpm) Catalog | Fans | CaptiveAire | Fan rated 0.71 m³/s at 1.50 kW. | NA | Open in the builder |
| Grundfos TP 100-330/4 in-line pump, 4-pole Catalog | Pumps | Grundfos | Pump rated 29.17 kg/s at 12.33 kW. | EU | Open in the builder |
| Powrmatic NVx 60 gas unit heater (60 kW output) Catalog | Heaters | Powrmatic | Air heater, 60.0 kW at 1.86 m³/s. | EU | Open in the builder |
| Sigma SRK-W-5-CV2-3H-4CC panel radiator (wall mount, CV2-3H-4CC coil), per foot Catalog | Radiators and emitters | Sigma | Hydronic emitter rated per foot of active length: 0.349 kW at an excess of 52.8 K, exponent 1.3. | NA | Open in the builder |
| Danfoss HCP094T2 (R407C scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R407C compressor — 21.6 kW cooling, 6.63 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point. | | Open in the builder |
| DRI HRW-5000-MS 200 (N) total energy recovery wheel Catalog AHRI 1060 (air-to-air energy recovery component) | Recovery cores | DRI | Sensible-and-latent recovery core, 9.465 m² face a stream, 18.93 / 18.93 m³/s. | NA | Open in the builder |
| Carnes VGBA 32 twin belt-drive forward-curved duct blower (two 12.5 in. wheels, 1427 rpm, 3 HP) Catalog | Fans | Carnes | Fan rated 1.70 m³/s at 2.32 kW. | NA | Open in the builder |
| KSB Etaline L 080-080-125 in-line pump, 1450 rpm Catalog | Pumps | KSB | Pump rated 6.20 kg/s at 0.50 kW. | EU | Open in the builder |
| King KFUH2040-3-2S3-ECM electric unit heater (40 kW, 208 V 3-phase) Catalog | Heaters | King Electric | Air heater, 40.0 kW at 1.38 m³/s. | NA | Open in the builder |