Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 4,633–4,656 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss DCJ106T4 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 31.5 kW cooling, 9.67 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NJ9226GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 3.1 kW cooling, 1.69 kW input, COP 1.87 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW55J7-100 (R134a heat-pump water heater scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR134a compressor — 6.3 kW cooling, 2.00 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2446P-HZ3A (R455A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR455A compressor — 0.68 kW cooling, 0.70 kW input, COP 0.97 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ASM14C1E-IAZ (R404A hermetic recip, 50 Hz, MT) CatalogCompressorsCopelandR404A compressor — 0.25 kW cooling, 0.23 kW input, COP 1.11 at -20/45 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss DSF175-4 (R32 scroll, 60 Hz, HT) CatalogCompressorsDanfossR32 compressor — 51.6 kW cooling, 15.70 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT2178GKV (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 0.54 kW cooling, 0.50 kW input, COP 1.07 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF29E3G-Q100 (R448A low-temperature freezing scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR448A compressor — 3.6 kW cooling, 3.18 kW input, COP 1.14 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh FH2511Z-KZ1A (R448A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 2.1 kW cooling, 1.73 kW input, COP 1.19 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland CF06K7ME-TFD (R404A hermetic recip, 50 Hz, LT) CatalogCompressorsCopelandR404A compressor — 1.3 kW cooling, 1.08 kW input, COP 1.21 at -30/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss DSH105-9 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 32.3 kW cooling, 10.06 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EGAS90HLR (R134a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.19 kW cooling, 0.13 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH200T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR407C compressor — 23.2 kW cooling, 7.18 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AE2425Z-AA3C (R448A hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 0.59 kW cooling, 0.41 kW input, COP 1.44 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland CR16K6E-PFV (R407C hermetic recip, 50 Hz, AC) CatalogCompressorsCopelandR407C compressor — 3.6 kW cooling, 1.26 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss HLH068T2 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 16.9 kW cooling, 5.26 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2P60CLP (R600a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.13 kW cooling, 0.10 kW input, COP 1.30 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM43E5G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 8.0 kW cooling, 3.37 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2519Z-TZ1A (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 2.0 kW cooling, 1.92 kW input, COP 1.02 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland CS10K6ME-TFD (R404A hermetic recip, 60 Hz, MT) CatalogCompressorsCopelandR404A compressor — 1.2 kW cooling, 0.96 kW input, COP 1.25 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLJ075T2A (R454B scroll, 60 Hz) CatalogCompressorsDanfossR454B compressor — 21.1 kW cooling, 6.51 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMC3130U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.25 kW cooling, 0.15 kW input, COP 1.70 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW630C1-100 (R410A heat-pump water heater scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR410A compressor — 68.0 kW cooling, 21.44 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AGB4561ZTZ (R407C hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR407C compressor — 11.8 kW cooling, 5.00 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
‹ Previous1…192193194195196…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one