Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 4,873–4,896 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss LLZ013T4A (R448A scroll, 60 Hz, LT) CatalogCompressorsDanfossR448A compressor — 3.1 kW cooling, 2.18 kW input, COP 1.41 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EMC3130U (R290 hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.30 kW cooling, 0.19 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW75T1-100 (R407C heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR407C compressor — 9.5 kW cooling, 3.22 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2521U-TZ1A (R290 hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR290 compressor — 2.7 kW cooling, 2.54 kW input, COP 1.07 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ZH06K1E-PFJ (R454C scroll, 50 Hz, HP) CatalogCompressorsCopelandR454C compressor — 6.8 kW cooling, 2.34 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MLM076T4 (R22 scroll, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 28.3 kW cooling, 8.52 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMI50HER (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.12 kW cooling, 0.09 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF35A1G-Q100 (R22 low-temperature freezing scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR22 compressor — 4.6 kW cooling, 3.45 kW input, COP 1.34 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AGB4568ZKZ (R22 hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR22 compressor — 18.4 kW cooling, 7.68 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZHT250KCE-TED (R513A scroll, 60 Hz, HR) CatalogCompressorsCopelandR513A compressor — 112.9 kW cooling, 38.82 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ015T2 (R407C scroll, 50 Hz, MT) CatalogCompressorsDanfossR407C compressor — 5.7 kW cooling, 1.86 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT30CDP (R600a hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.26 kW cooling, 0.12 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH230C7-100 (R410A air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR410A compressor — 27.9 kW cooling, 8.75 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2446P-TZ1A (R454C hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR454C compressor — 0.57 kW cooling, 0.59 kW input, COP 0.96 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ZJ22KHE-PFZ (R410A scroll, 50 Hz, AC) CatalogCompressorsCopelandR410A compressor — 5.4 kW cooling, 1.80 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss MT032-6 (R22 hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 8.1 kW cooling, 2.98 kW input, COP 2.70 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMU55CLR (R600a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.11 kW cooling, 0.08 kW input, COP 1.35 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM49A3G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR22 compressor — 9.4 kW cooling, 3.46 kW input, COP 2.71 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh FH2511Z-XG1A (R404A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 1.5 kW cooling, 1.56 kW input, COP 0.99 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ZP104K2E-TFD (R410A scroll, 50 Hz, AC) CatalogCompressorsCopelandR410A compressor — 25.6 kW cooling, 7.96 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MTZ018-4 (R407A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR407A compressor — 4.3 kW cooling, 1.81 kW input, COP 2.37 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMX3115Y (R600a hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.13 kW cooling, 0.09 kW input, COP 1.50 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW75T2-102 (R407C heat-pump water heater scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR407C compressor — 7.9 kW cooling, 2.82 kW input, COP 2.82 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AE4425P-FZ1A (R404A hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 0.67 kW cooling, 0.30 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
‹ Previous1…202203204205206…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one