Copeland ZR24K3E-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 7.2 kW cooling, 2.24 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR24K4E-PFJ (R407C scroll, 50 Hz, AC)
R407C compressor — 5.5 kW cooling, 1.90 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR24K4E-PFV (R407C scroll, 60 Hz, AC)
R407C compressor — 6.5 kW cooling, 2.16 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR24KTE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 5.7 kW cooling, 1.92 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR24KTE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 7.2 kW cooling, 2.24 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR250KCE-TED (R134A scroll, 50 Hz, AC)
R134a compressor — 40.1 kW cooling, 12.23 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR250KCE-TED (R134A scroll, 60 Hz, AC)
R134a compressor — 48.7 kW cooling, 15.08 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR250KCE-TED (R407C scroll, 50 Hz, AC)
R407C compressor — 58.5 kW cooling, 17.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR250KCE-TED (R407C scroll, 60 Hz, AC)
R407C compressor — 70.4 kW cooling, 21.66 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR25K5E-TFD (R22 scroll, 50 Hz, AC)
R22 compressor — 6.0 kW cooling, 1.92 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR25K5E-TFD (R22 scroll, 60 Hz, AC)
R22 compressor — 7.4 kW cooling, 2.32 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR25K5E-PFJ (R407C scroll, 50 Hz, AC)
R407C compressor — 5.8 kW cooling, 2.00 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR25K5E-TF5 (R407C scroll, 60 Hz, AC)
R407C compressor — 7.1 kW cooling, 2.34 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR26K3E-PFJ (R407C scroll, 50 Hz, AC)
R407C compressor — 6.0 kW cooling, 2.01 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR26K3E-TF5 (R407C scroll, 60 Hz, AC)
R407C compressor — 7.7 kW cooling, 2.49 kW input, COP 3.09 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR26K5E-PFV (R407C scroll, 60 Hz, AC)
R407C compressor — 7.3 kW cooling, 2.45 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR28K3E-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 6.6 kW cooling, 2.14 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR28K3E-TF5 (R407C scroll, 60 Hz, AC)
R407C compressor — 8.0 kW cooling, 2.53 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR28K5-TF7 (R22 scroll, 60 Hz, AC)
R22 compressor — 8.3 kW cooling, 2.59 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR28K5E-TFD (R22 scroll, 50 Hz, AC)
R22 compressor — 6.8 kW cooling, 2.13 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR28K5E-TFD (R22 scroll, 60 Hz, AC)
R22 compressor — 8.3 kW cooling, 2.59 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR28K5E-TF5 (R407C scroll, 50 Hz, AC)
R407C compressor — 6.6 kW cooling, 2.15 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR28K5E-TF7 (R407C scroll, 60 Hz, AC)
R407C compressor — 8.0 kW cooling, 2.66 kW input, COP 3.01 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR28KTE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 6.6 kW cooling, 2.14 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.