Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 5,281–5,304 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AGB4568ZTZ (R407C hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR407C compressor — 16.9 kW cooling, 7.17 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DHXF63KL-TSK (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 14.7 kW cooling, 8.37 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH023-4G (R454B scroll, 60 Hz) CatalogCompressorsDanfossR454B compressor — 29.5 kW cooling, 9.91 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMI55HER (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.12 kW cooling, 0.09 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH266T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR407C compressor — 30.8 kW cooling, 9.38 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2446Z-GZ3B (R448A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 0.61 kW cooling, 0.63 kW input, COP 0.96 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DHXR22M0-AWX (R22 Discus recip, 60 Hz, MT) CatalogCompressorsCopelandR22 compressor — 73.9 kW cooling, 23.97 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SH161-7 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 47.1 kW cooling, 14.43 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT30HHR (R134a hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.31 kW cooling, 0.15 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM49E8G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 575 V 3P) CatalogCompressorsInvotechR404A compressor — 9.1 kW cooling, 3.72 kW input, COP 2.45 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh FH4518N-XC3A (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 4.0 kW cooling, 1.50 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DHXS16ML-TSK (R407A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407A compressor — 32.8 kW cooling, 12.31 kW input, COP 2.67 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SM125-4 (R22 scroll, 50 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 30.1 kW cooling, 8.93 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMU60HSC (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF35E3G-Q100 (R449A low-temperature freezing scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR449A compressor — 4.3 kW cooling, 3.72 kW input, COP 1.15 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AE4425Z-AA1A (R449A hermetic, HBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 0.80 kW cooling, 0.33 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJ3R28ML-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 47.5 kW cooling, 17.00 kW input, COP 2.80 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SZ100-9 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 26.5 kW cooling, 8.18 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMX3118Y (R600a hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.17 kW cooling, 0.11 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH266T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P) CatalogCompressorsInvotechR407C compressor — 30.8 kW cooling, 9.38 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2522Z-TZ1A (R448A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 2.7 kW cooling, 2.53 kW input, COP 1.08 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DJNF76KE-TSK (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 18.2 kW cooling, 10.34 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss VZH044CGM (R454B inverter scroll, A/C) CatalogCompressorsDanfossR454B compressor — 20.6 kW cooling, 7.23 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY45HER (R134a hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.09 kW cooling, 0.07 kW input, COP 1.28 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
‹ Previous1…219220221222223…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here