Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 5,329–5,352 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Embraco NJ9238GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 2.5 kW cooling, 1.53 kW input, COP 1.64 at -15/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH292C1-100 (R410A air-conditioning scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR410A compressor — 35.3 kW cooling, 10.96 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AGB4568ZTZ (R448A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 17.5 kW cooling, 7.61 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DKNR22ME-TSK (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 80.0 kW cooling, 25.26 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HRH032U4A (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 9.1 kW cooling, 3.21 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT2192GKA (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 0.56 kW cooling, 0.52 kW input, COP 1.08 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM60A1G-100 (R22 medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 9.6 kW cooling, 3.35 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AJ2446Z-GZ3B (R452A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 0.49 kW cooling, 0.56 kW input, COP 0.88 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DKNS16ME-TSK (R449A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR449A compressor — 33.7 kW cooling, 12.52 kW input, COP 2.69 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM042T4 (R22 scroll, 50 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 10.1 kW cooling, 3.08 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2S75HLP (R134a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.13 kW cooling, 0.09 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF35E5G-Q100 (R404A low-temperature freezing scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 4.7 kW cooling, 3.78 kW input, COP 1.24 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh FH4518N-XG1A (R1234yf hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR1234yf compressor — 3.5 kW cooling, 1.40 kW input, COP 2.47 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DRNF76KE-TSK (R448A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR448A compressor — 19.5 kW cooling, 11.01 kW input, COP 1.77 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRP047T2 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 11.1 kW cooling, 3.69 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMC3140U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.33 kW cooling, 0.21 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH292C5-100 (R410A air-conditioning scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR410A compressor — 35.3 kW cooling, 10.96 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AE4425Z-FZ1A (R404A hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 0.67 kW cooling, 0.30 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DRNR28ME-TSK (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 87.7 kW cooling, 29.41 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss LLZ013T4B (R454C scroll, 50 Hz, LT) CatalogCompressorsDanfossR454C compressor — 2.7 kW cooling, 1.70 kW input, COP 1.61 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EMI60HEP (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.13 kW cooling, 0.11 kW input, COP 1.18 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM60A1G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR22 compressor — 11.5 kW cooling, 4.05 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2522Z-TZ1A (R449A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 2.7 kW cooling, 2.53 kW input, COP 1.08 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4YANF36KE-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 10.4 kW cooling, 5.98 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…221222223224225…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one