Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 5,353–5,376 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss MLM160T4 (R22 scroll, 50 Hz) CatalogCompressorsDanfossR22 compressor — 56.7 kW cooling, 18.38 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT30HHR (R134a hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.31 kW cooling, 0.15 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF35E5G-V100 (R404A low-temperature freezing scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 5.9 kW cooling, 4.27 kW input, COP 1.37 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AGB4568ZTZ (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 14.6 kW cooling, 5.91 kW input, COP 2.47 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YAXF36KE-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 10.4 kW cooling, 5.98 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T2C (R22 scroll, 60 Hz, MT) CatalogCompressorsDanfossR22 compressor — 6.7 kW cooling, 2.21 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMU6132Y (R600a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.36 kW cooling, 0.15 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH292C6-100 (R410A air-conditioning scroll, 50 Hz, 220 V 3P) CatalogCompressorsInvotechR410A compressor — 29.5 kW cooling, 9.15 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AJ2446Z-HZ3B (R404A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 0.63 kW cooling, 0.74 kW input, COP 0.84 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4YBNF40KL-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 11.6 kW cooling, 6.64 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT036-4 (R22 hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 11.1 kW cooling, 4.05 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMX3118Y (R600a hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.55 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM60A2G-100 (R22 medium-temperature refrigeration scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR22 compressor — 9.6 kW cooling, 3.30 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh FH4518N-XG1A (R1234yf hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR1234yf compressor — 4.1 kW cooling, 1.75 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YBXF40KE-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 11.6 kW cooling, 6.64 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ018-4 (R448A hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR448A compressor — 3.6 kW cooling, 1.47 kW input, COP 2.43 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY45HSC (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.10 kW cooling, 0.07 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF35E7G-Q100 (R404A low-temperature freezing scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR404A compressor — 4.7 kW cooling, 3.78 kW input, COP 1.24 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AE4425Z-FZ1A (R448A hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 0.80 kW cooling, 0.33 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YCNF40KE-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 11.6 kW cooling, 6.64 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss NTZ068-4B (R404A hermetic reciprocating, 60 Hz, LT) CatalogCompressorsDanfossR404A compressor — 1.2 kW cooling, 1.51 kW input, COP 0.82 at -40/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco FFI8,5HAK (R134a hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.18 kW cooling, 0.14 kW input, COP 1.30 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH292C7-100 (R410A air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR410A compressor — 35.3 kW cooling, 10.96 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2522Z-TZ1A (R449A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 3.5 kW cooling, 3.27 kW input, COP 1.07 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
‹ Previous1…222223224225226…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one