Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 5,449–5,472 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Embraco NT2192GKV (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 0.57 kW cooling, 0.53 kW input, COP 1.06 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH307A6-100 (R22 air-conditioning scroll, 50 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 30.9 kW cooling, 8.87 kW input, COP 3.48 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AG2525P-TZ1A (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 2.6 kW cooling, 2.46 kW input, COP 1.04 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DHNR35M0-AWX (R22 Discus recip, 60 Hz, MT) CatalogCompressorsCopelandR22 compressor — 110.1 kW cooling, 36.14 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ015T2C (R404A scroll, 50 Hz, MT) CatalogCompressorsDanfossR404A compressor — 4.9 kW cooling, 2.08 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2T60CLP (R600a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.12 kW cooling, 0.10 kW input, COP 1.19 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM60E1G-100 (R448A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR448A compressor — 9.9 kW cooling, 3.51 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AGB4573ZKZ (R22 hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 16.2 kW cooling, 6.83 kW input, COP 2.37 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DHXF93KE-TSK (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 22.2 kW cooling, 13.20 kW input, COP 1.68 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT036-5 (R22 hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 9.3 kW cooling, 3.37 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMC3140U (R290 hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.33 kW cooling, 0.21 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF41A1G-Q100 (R22 low-temperature freezing scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR22 compressor — 5.4 kW cooling, 4.01 kW input, COP 1.35 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AJ2446Z-TZ1B (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 0.51 kW cooling, 0.57 kW input, COP 0.90 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DHXR35ME-TSK (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 110.6 kW cooling, 34.20 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MTZ018-4 (R448A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR448A compressor — 4.3 kW cooling, 1.88 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMI60HER (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.14 kW cooling, 0.11 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH307A7-100 (R22 air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 37.0 kW cooling, 10.63 kW input, COP 3.48 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh FH4518N-XG1A (R513A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR513A compressor — 4.7 kW cooling, 1.82 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DJNF11ME-TSK (R407C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407C compressor — 22.4 kW cooling, 14.71 kW input, COP 1.52 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss NTZ068-4B (R452A hermetic reciprocating, 50 Hz, LT) CatalogCompressorsDanfossR452A compressor — 1.5 kW cooling, 1.33 kW input, COP 1.10 at -35/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EMT32CLP (R600a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.08 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM60E1G-100 (R449A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR449A compressor — 9.9 kW cooling, 3.51 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AE4425Z-GS1A (R404A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 0.66 kW cooling, 0.35 kW input, COP 1.90 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DJNR40M0-AWX (R22 Discus recip, 60 Hz, MT) CatalogCompressorsCopelandR22 compressor — 127.9 kW cooling, 44.34 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
‹ Previous1…226227228229230…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one