Embraco EMC3121U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.22 kW cooling, 0.13 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3121U (R290 hermetic, MBP, EN12900, 50-60 Hz)
R290 compressor — 0.23 kW cooling, 0.13 kW input, COP 1.75 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3121U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 0.20 kW cooling, 0.12 kW input, COP 1.66 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3121U (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.22 kW cooling, 0.13 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3125U (R290 hermetic, LBP, EN12900, 50-60 Hz)
R290 compressor — 0.26 kW cooling, 0.15 kW input, COP 1.70 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3125U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.23 kW cooling, 0.13 kW input, COP 1.75 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3125U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.26 kW cooling, 0.16 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3125U (R290 hermetic, MBP, EN12900, 50-60 Hz)
R290 compressor — 0.26 kW cooling, 0.15 kW input, COP 1.70 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3125U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 0.23 kW cooling, 0.13 kW input, COP 1.75 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3125U (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.26 kW cooling, 0.16 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3130U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.25 kW cooling, 0.15 kW input, COP 1.70 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3130U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.30 kW cooling, 0.19 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3130U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 0.25 kW cooling, 0.15 kW input, COP 1.70 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3130U (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.30 kW cooling, 0.19 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3134U (R290 hermetic, LBP, EN12900, 50-60 Hz)
R290 compressor — 0.36 kW cooling, 0.21 kW input, COP 1.72 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3134U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.31 kW cooling, 0.19 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3134U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.38 kW cooling, 0.22 kW input, COP 1.78 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3134U (R290 hermetic, MBP, EN12900, 50-60 Hz)
R290 compressor — 0.36 kW cooling, 0.21 kW input, COP 1.72 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3134U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 0.31 kW cooling, 0.19 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3134U (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.38 kW cooling, 0.22 kW input, COP 1.78 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3140U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.33 kW cooling, 0.21 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3140U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.43 kW cooling, 0.27 kW input, COP 1.59 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3140U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 0.33 kW cooling, 0.21 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMC3140U (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.43 kW cooling, 0.27 kW input, COP 1.59 at -30/40 °C (evaporating/condensing), inside its published envelope.