Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 5,785–5,808 of 10,248
Embraco EME60HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMH60HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.14 kW cooling, 0.10 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI28HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.11 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI28HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.11 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI30CEP (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.05 kW cooling, 0.05 kW input, COP 1.02 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI30CNP (R600a hermetic, LBP, ASHRAE, 50-60 Hz)
R600a compressor — 0.06 kW cooling, 0.07 kW input, COP 0.89 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI30CNP (R600a hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.06 kW cooling, 0.07 kW input, COP 0.82 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI30HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.08 kW cooling, 0.07 kW input, COP 1.14 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI30HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.08 kW cooling, 0.07 kW input, COP 1.14 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI30HER (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.07 kW cooling, 0.07 kW input, COP 1.06 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI30HEX (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.08 kW cooling, 0.06 kW input, COP 1.30 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI30HEX (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.21 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI32CLP (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.07 kW cooling, 0.07 kW input, COP 1.00 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI40CNC (R600a hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.08 kW cooling, 0.07 kW input, COP 1.04 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI40CNC (R600a hermetic, LBP, ASHRAE, 60 Hz)
R600a compressor — 0.09 kW cooling, 0.08 kW input, COP 1.18 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI40CNP (R600a hermetic, LBP, ASHRAE, 50-60 Hz)
R600a compressor — 0.09 kW cooling, 0.08 kW input, COP 1.12 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI40CNP (R600a hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.08 kW cooling, 0.08 kW input, COP 1.04 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI40HNP (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.10 kW cooling, 0.09 kW input, COP 1.09 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI40HNR (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.09 kW cooling, 0.08 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI45HEP (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.08 kW cooling, 0.08 kW input, COP 0.97 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI45HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.30 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI45HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI50HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.12 kW cooling, 0.10 kW input, COP 1.22 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI50HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.12 kW cooling, 0.09 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope.
Publishing here