Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 5,809–5,832 of 10,248
Embraco EMI50UER (R290 hermetic, LBP, EN12900, 50-60 Hz)
R290 compressor — 0.11 kW cooling, 0.09 kW input, COP 1.24 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI50UER (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.11 kW cooling, 0.09 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI50UER (R290 hermetic, MBP, EN12900, 50-60 Hz)
R290 compressor — 0.11 kW cooling, 0.09 kW input, COP 1.24 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI50UER (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.11 kW cooling, 0.09 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI55HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.12 kW cooling, 0.09 kW input, COP 1.31 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI55HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.12 kW cooling, 0.09 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI60HEP (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.13 kW cooling, 0.11 kW input, COP 1.18 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI60HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.14 kW cooling, 0.11 kW input, COP 1.31 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI60HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.14 kW cooling, 0.11 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI60HSR (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.13 kW cooling, 0.10 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI70HDR (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.65 kW cooling, 0.32 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.
Embraco EMI70HER (R134a hermetic, LBP, ASHRAE, 50 Hz)
R134a compressor — 0.13 kW cooling, 0.11 kW input, COP 1.20 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI70HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.16 kW cooling, 0.12 kW input, COP 1.36 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI70HNR (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.17 kW cooling, 0.15 kW input, COP 1.15 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI70HNR (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.16 kW cooling, 0.15 kW input, COP 1.06 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI70UER (R290 hermetic, LBP, EN12900, 50-60 Hz)
R290 compressor — 0.16 kW cooling, 0.13 kW input, COP 1.19 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI70UER (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.16 kW cooling, 0.13 kW input, COP 1.19 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI70UER (R290 hermetic, MBP, EN12900, 50-60 Hz)
R290 compressor — 0.16 kW cooling, 0.13 kW input, COP 1.19 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI70UER (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.16 kW cooling, 0.13 kW input, COP 1.19 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI90UEX (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.21 kW cooling, 0.17 kW input, COP 1.20 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMI90UEX (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.21 kW cooling, 0.17 kW input, COP 1.20 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMIE30HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.07 kW cooling, 0.05 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMIE30HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.20 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMIE30HER (R134a hermetic, MBP, EN12900, 50-60 Hz)
R134a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.16 at -30/40 °C (evaporating/condensing), inside its published envelope.
Publishing here