Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 5,881–5,904 of 10,248
Embraco EMRS46CLP (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.09 kW cooling, 0.07 kW input, COP 1.40 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMS32CLP (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.71 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMS40CLP (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.10 kW cooling, 0.06 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMSS40CLP (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.09 kW cooling, 0.06 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMSS46CLP (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.10 kW cooling, 0.06 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMSS66CLC (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT1110L (R1234yf hermetic, LBP, EN12900, 50-60 Hz)
R1234yf compressor — 0.10 kW cooling, 0.08 kW input, COP 1.24 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT1117U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.12 kW cooling, 0.11 kW input, COP 1.15 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT1121U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.17 kW cooling, 0.15 kW input, COP 1.14 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT1125U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.17 kW cooling, 0.14 kW input, COP 1.22 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT1130U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.20 kW cooling, 0.18 kW input, COP 1.10 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT2117GK (R404A hermetic, LBP, EN12900, 50 Hz)
R404A compressor — 0.14 kW cooling, 0.13 kW input, COP 1.05 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT2117U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.12 kW cooling, 0.11 kW input, COP 1.10 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT2121GK (R404A hermetic, LBP, EN12900, 50 Hz)
R404A compressor — 0.17 kW cooling, 0.16 kW input, COP 1.08 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT2121U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.13 kW cooling, 0.11 kW input, COP 1.12 at -40/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT2125GK (R404A hermetic, LBP, EN12900, 50 Hz)
R404A compressor — 0.20 kW cooling, 0.18 kW input, COP 1.11 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT2125U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.14 kW cooling, 0.12 kW input, COP 1.13 at -40/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT2130GK (R404A hermetic, LBP, EN12900, 50 Hz)
R404A compressor — 0.21 kW cooling, 0.21 kW input, COP 1.04 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT2130U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.19 kW cooling, 0.18 kW input, COP 1.10 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT22HLP (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.09 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT23CLP (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT26CLP (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.16 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT26CLP (R600a hermetic, MBP, EN12900, 50 Hz)
R600a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.08 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT28HLP (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.06 kW cooling, 0.06 kW input, COP 1.06 at -30/40 °C (evaporating/condensing), inside its published envelope.
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one