Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 5,977–6,000 of 10,248
Embraco EMU40CLP (R600a hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.09 kW cooling, 0.07 kW input, COP 1.20 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU40CLP (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.08 kW cooling, 0.07 kW input, COP 1.22 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU45HEP (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.28 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU45HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU45HLP (R134a hermetic, LBP, ASHRAE, 50 Hz)
R134a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.36 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU45HSC (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.11 kW cooling, 0.07 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU45HSC (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.10 kW cooling, 0.07 kW input, COP 1.39 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU46CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.20 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU46CLP (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.09 kW cooling, 0.07 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU5125Y (R600a hermetic, HBP, EN12900, 50 Hz)
R600a compressor — 0.24 kW cooling, 0.10 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
Embraco EMU5132Y (R600a hermetic, HBP, EN12900, 50 Hz)
R600a compressor — 0.36 kW cooling, 0.15 kW input, COP 2.32 at the AHRI 7.2/54.4 °C rating point.
Embraco EMU55CLR (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.11 kW cooling, 0.08 kW input, COP 1.35 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU55HLP (R134a hermetic, LBP, ASHRAE, 50 Hz)
R134a compressor — 0.12 kW cooling, 0.08 kW input, COP 1.38 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU55HLP (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.28 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU60CLP (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.10 kW input, COP 1.17 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU60HEP (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.14 kW cooling, 0.10 kW input, COP 1.38 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU60HLC (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.13 kW cooling, 0.10 kW input, COP 1.31 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU60HSC (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU6132Y (R600a hermetic, HBP, EN12900, 50 Hz)
R600a compressor — 0.36 kW cooling, 0.15 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.
Embraco EMU65HLP (R134a hermetic, LBP, ASHRAE, 50 Hz)
R134a compressor — 0.17 kW cooling, 0.11 kW input, COP 1.53 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU66CLR (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.13 kW cooling, 0.10 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU70HLC (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.11 kW cooling, 0.10 kW input, COP 1.16 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMUE40CLP (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.08 kW cooling, 0.07 kW input, COP 1.09 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMUE60CLP (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.13 kW cooling, 0.10 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.
Publishing here