Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 5,953–5,976 of 10,248
Embraco EMT6160Y (R600a hermetic, HBP, EN12900, 50 Hz)
R600a compressor — 0.58 kW cooling, 0.29 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
Embraco EMT6160Z (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 0.66 kW cooling, 0.30 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point.
Embraco EMT6165GK (R404A hermetic, MBP, EN12900, 50 Hz)
R404A compressor — 0.71 kW cooling, 0.39 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
Embraco EMT6165U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 0.76 kW cooling, 0.33 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
Embraco EMT6170Z (R134a hermetic, HBP, EN12900, 50-60 Hz)
R134a compressor — 0.79 kW cooling, 0.35 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point.
Embraco EMT6170Z (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 0.70 kW cooling, 0.36 kW input, COP 1.95 at the AHRI 7.2/54.4 °C rating point.
Embraco EMT65HLC (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.13 kW cooling, 0.11 kW input, COP 1.18 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT65HLR (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.14 kW cooling, 0.11 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT75HLC (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.15 kW cooling, 0.13 kW input, COP 1.17 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMT75HLP (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.15 kW cooling, 0.12 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMTE2134U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.21 kW cooling, 0.18 kW input, COP 1.17 at -40/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMTE6181U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 0.92 kW cooling, 0.37 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.
Embraco EMTE6187Z (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 0.85 kW cooling, 0.37 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.
Embraco EMTS2125U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.25 kW cooling, 0.15 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU26CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.22 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU26CLC (R600a hermetic, MBP, EN12900, 50 Hz)
R600a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.17 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU30CLP (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.13 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU30HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU30HER (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.66 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU30HSC (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.08 kW cooling, 0.06 kW input, COP 1.31 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU32CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.08 kW cooling, 0.06 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU32CLC (R600a hermetic, MBP, EN12900, 50 Hz)
R600a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.22 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU40CLC (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.09 kW cooling, 0.07 kW input, COP 1.28 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMU40CLC (R600a hermetic, MBP, EN12900, 50 Hz)
R600a compressor — 0.09 kW cooling, 0.07 kW input, COP 1.28 at -30/40 °C (evaporating/condensing), inside its published envelope.
Publishing here