Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 6,097–6,120 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Copeland 2YA3F17KL-TFC (R454C Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R454C compressor — 4.9 kW cooling, 2.84 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ018-4 (R454C hermetic reciprocating, 50 Hz, MT) Catalog | Compressors | Danfoss | R454C compressor — 3.2 kW cooling, 1.30 kW input, COP 2.49 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMX4130U (R290 hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R290 compressor — 0.30 kW cooling, 0.20 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM70E7G-100 (R449A medium-temperature refrigeration scroll, 60 Hz, 220 V 3P) Catalog | Compressors | Invotech | R449A compressor — 13.5 kW cooling, 5.14 kW input, COP 2.63 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AG2525Z-TZ1A (R452A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R452A compressor — 2.4 kW cooling, 2.39 kW input, COP 0.99 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 2YB3F18KL-TFC (R454C Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R454C compressor — 5.1 kW cooling, 2.98 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss NTZ068-5B (R452A hermetic reciprocating, 50 Hz, LT) Catalog | Compressors | Danfoss | R452A compressor — 1.5 kW cooling, 1.50 kW input, COP 0.97 at -35/45 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Embraco EMY60HSC (R134a hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF80E1G-Q100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P) Catalog | Compressors | Invotech | R404A compressor — 8.9 kW cooling, 7.22 kW input, COP 1.24 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AGB4581ZKZ (R404A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R404A compressor — 16.1 kW cooling, 7.97 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 2YC3R51KL-TFC (R454C Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R454C compressor — 8.2 kW cooling, 2.93 kW input, COP 2.79 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss PSH026-3G (R454B scroll, 60 Hz) Catalog | Compressors | Danfoss | R454B compressor — 33.5 kW cooling, 11.13 kW input, COP 3.01 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NEK6160Z (R134a hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.76 kW cooling, 0.36 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH69A2-102 (R22 air-conditioning scroll, 50 Hz, 220 V 1P) Catalog | Compressors | Invotech | R22 compressor — 6.9 kW cooling, 2.25 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh AJ2464P-HZ3A (R454C hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R454C compressor — 0.82 kW cooling, 0.87 kW input, COP 0.95 at -30/50 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 2YD3R59KL-TFC (R454C Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R454C compressor — 9.5 kW cooling, 3.40 kW input, COP 2.78 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss SH180-9 (R410A scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R410A compressor — 53.7 kW cooling, 16.45 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NEU6212GK (R404A hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R404A compressor — 1.4 kW cooling, 0.72 kW input, COP 1.96 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM70E7G-100 (R452A medium-temperature refrigeration scroll, 60 Hz, 220 V 3P) Catalog | Compressors | Invotech | R452A compressor — 12.9 kW cooling, 5.31 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh FH4522U-XG1A (R290 hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R290 compressor — 5.6 kW cooling, 2.05 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 2YL3F15KL-TFC (R454C Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R454C compressor — 4.3 kW cooling, 2.52 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss SM148-3 (R22 scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 43.8 kW cooling, 13.01 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NT6217GK (R404A hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R404A compressor — 1.8 kW cooling, 0.98 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF80E1G-Q100 (R404A low-temperature freezing scroll, 60 Hz, 460 V 3P) Catalog | Compressors | Invotech | R404A compressor — 10.7 kW cooling, 8.66 kW input, COP 1.24 at -30/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory