Embraco EMYS65HSP (R134a hermetic, LBP, EN12900, 50-60 Hz)
R134a compressor — 0.16 kW cooling, 0.10 kW input, COP 1.57 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMYS70HEP (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.14 kW cooling, 0.11 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMYS75HSP (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMYS80HSP (R134a hermetic, LBP, ASHRAE, 50 Hz)
R134a compressor — 0.16 kW cooling, 0.08 kW input, COP 1.90 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ20CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.05 kW cooling, 0.03 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ26CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.06 kW cooling, 0.04 kW input, COP 1.50 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ32CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.07 kW cooling, 0.05 kW input, COP 1.59 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ32CLP (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.71 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ40CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.09 kW cooling, 0.06 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ40CLP (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.10 kW cooling, 0.06 kW input, COP 1.63 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ46CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.11 kW cooling, 0.07 kW input, COP 1.57 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ55CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.12 kW cooling, 0.07 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ55CLT (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.08 kW input, COP 1.60 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ60CLC (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.68 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ60CLT (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ66CLP (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.16 kW cooling, 0.09 kW input, COP 1.81 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ70CLC (R600a hermetic, LBP, ASHRAE, 50 Hz)
R600a compressor — 0.15 kW cooling, 0.09 kW input, COP 1.68 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZ90HLC (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.15 kW cooling, 0.11 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EMZS55CLC (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco ESB55CBT (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.07 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco ESC+55CBT (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.07 kW input, COP 1.71 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco ESC55CBT (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.07 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco ESU55CBC (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.08 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco ESU55CBP (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.08 kW input, COP 1.40 at -30/40 °C (evaporating/condensing), inside its published envelope.